Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

06/22/2006

Applicant:

NELSON LIVING TRUST

Description:

WARD 6 REFERRAL: WINDOWS COVERED WITH PLYWOOD, WATER DRIPPING OFF ROOF FROM COOLER, AND BATHROOM FLOOR READY TO "FALL-IN."

Outstanding Inspections

Case Number: T06DV00697
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T06DV00697
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/02/2006 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE ON F/U INSPECTION, MET WITH OWNERS WALKED PROPERTY TO REVIEW COMPLETED REPAIR REQUESTED ON NOV ISSUED ON 6-22-06. FINDING ARE AS FOLLOWS: 1. TC 16-11 (B2) COOLING SYSTEM VIOLATION ABATED. GOOD USED COOLER HAS BEEN INSTALLED ALONG WITH NEW RISER AND ROOF JACK, ROOF JACK HAS BEEN SEALED. 2. TC 16-12 (A) EXTERIOR STRUCTURE, EXTERIOR STRUCTURES WEATER PROTECTION (2) VIOLATION ABATED: MAIN STRUCTURE (MOBILE HOME) FACSIA HAS BEEN PREPED AND REPAINTED, 2ND STRUCTURE HAS BEEN COMPLETLY PAINTED. WOODEN FENCING ON WESTSIDE IS APPROXIMETLY 80% COMPLETE SOME STRIPING STILL REMAINS ON 1 TEN FOOT SECTION & THEN OWNER WILL HAVE SECTION PAINTED. 3. TC 16-11 (C) ELECT SYS VIOLATION ABATED: WEATHER PROTECTION COVER INSTALLED AT EXTERIOR RECEP. 4. TC 16-11 (E) ACCESSORY STRUCTURE LANDINGS VIOLATION NOT ABATED: 1 SECTION HAD BEEN REPAIRED & PAINTED LANDING BY SLIDING GLASS DOOR IS BEING WORKED ON. OWNER REQUESTED EXTENTION TO COMPLETE REPAIRS & STATED SHOULD BE DONE WITHIN 30 DAYS. 5.TC 16-11 (E) ACCESSOR STRUCTURES (AWNING) VIOLATION ABATED: DELAPIDATED METAL AWNING USED AS CARPORT HAS BEEN REPAIRED, NEW STUDS INSTALLED & SECTION OF METAL CORRAGATED PANELS HAVE BEEN SECURED. OWNER HAS MADE GOOD PROGRESS. EXTENTION GRANTED DUE TO GOOD PROGRESS BY OWNER EXTENTION WILL BE GRANTED TO COMPLETE REPAIRS TO LANDING & COMPLETE WEATER PROTECTION ON REMAINING 20% OF WOOD FENCING. FW/UP IN 30 DAYS.
09/14/2006 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved OWNER HAS COMPLIED WITH NOV ISSUES, CASE COMPLIANCE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00697
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
07/12/2006 CONTACTED BY PHONE
06/28/2006 NOTICE OF VIOLATION ISSUED
11/01/2006 VIOLATION CLOSED

Documents

File Name Document Type  
5727 E PIMA ST LACKS PAINT PRO 2006-06-26 01.JPG IMAGES VIEW
5727 E PIMA ST COMPLAINCE 015.JPG IMAGES VIEW
5727 E PIMA ST COMPLAINCE 016.JPG IMAGES VIEW
5727 E PIMA ST COMPLAINCE 017.JPG IMAGES VIEW
5727 E PIMA ST COMPLAINCE 018.JPG IMAGES VIEW