Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

09/28/2004

Applicant:

NGUYEN LAN B & NG ANDY JT/RS

Description:

COMPLAINT:MIN HOUSING-BREAKER BOX LOCATED IN OTHER TENANT APT. WATER HEATER EXPOSED IN KITCHEN. HOLE IN BATHROOM WALL UNDER SINK.

Outstanding Inspections

Case Number: T04DV00797
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
End Date Description Inspector Results Comments
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - SMOKE ALARMS None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00797
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/06/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE INITIAL INSPECTION WAS DONE ON UNIT B, PRESENT WERE TENANTS & DNR INSP. VIOLATION ARE AS FOLLOWS. ELECTRICAL W/O/P: (1) ADDITION & ALTERATION TO ORIGINAL ELECTRICAL SYSTEM HAVE BEEN DONE. OUTSIDE ELECTRICAL DISCONNECT HAS BEEN REMOVED 1 1/2 GALVANIZED PIPE CONTACTING ELECTRICAL CONDUCTORS, RUNS FROM T.E.P. METER DOWN INTO GROUND. SUB PANEL IS IN UNIT A. UNIT HAS NO EMERGENCY SHUT OFF (DISCONNECT) IN CASE OF EMERGENCY. ELECTRICAL ALTERATION HAVE BEEN DONE IN A HAZARDOUS MANNER. (2) TEST EQUIPMENT WAS USED ON 3 SPRONG RECEPTACLES & WERE FOUND LACKING MECHANICAL GROUND. (3) NO GFIC IN KITCHEN. (4) ELECTRICAL SYSTEM IS A TWO WIRE SYSTEM, WILL REQUIRE DEADICATED CIRCUITS FOR KITCHEN RECEPTACLES W/ GFIC & 1 FOR REFRIGERATOR & ELECTRICAL UPGRADE. (5) NO GFIC IN BATHROOM. ORIGINAL 60 AMP SERVICE IS MOUNTED ON TOWER POLE, ELECTRICAL DISCONNECT IN A DETERIORATED & DELAPATATED STATE, LARGE AMOUNTS OF RUST & ELECTRICAL CONDUCTOR HAVE BEGUN TO CRACK. WEATHER PROOFING: (1) SEVERAL BROKEN WINDOWS THROUGH OUT STRUCTURE. (2) ENTRY DOOR REQUIRES ADJUSTMENT OF WEATHER STRIPPING. ACCESS CONTROL: (1) BATHROOM WINDOW CRANKS NOT WORKING. (2) NORTHEAST BEDROOM CRANK NOT WORKING. HEATING: (1) FURNACE REQUIRES SERVICING. PLUMBING: (1) ORIGINAL GAS PIPING HAS BEEN ALTERED, ADDITION OF GAS PIPING FOR NEW WALL MOUNTED HOT WATER HEATER BOSCH TYP-MAY BE 5 GAL. ONLY & OPERATES FOR BOTH A & B UNITS. (2) ADDITION OF WATER LINES W/ NEW METAL BRAIDED LINES, ORIGINAL HOT WATER HEATER HAS BEEN REMOVED. (3) SHUT OF FOR STOVE IS NOT READY ACCESSABLE, STOVE HAS TO BE PULLED OUT & REACH IN & AROUND CORNER CABINET. (4) POSSABLE WRONG APPLICATION OF HOT WATER HEATER IN KITCHEN, CHECK W/ PLUMBING INSP. (5) INCORRECT INSTALLATION OF SHUT OFF VALVE & HANDLE IS BROKEN. STRUCTURAL: (1) NEW WALL HAS BEEN ERECTED, INFORMATION FROM PREVIOUS OWNER NEXT DOOR VERIFIED ROOM HAS BEEN SPLIT, WALL HAS NO ELECTRICAL. FIRE PROTECTION: (1) LACKING REQUIRED WORKING SMOKE DETECTOR. INTERIOR FEATURES: (1) LARGE HOLE UNDER SINK PEDISTAL, EXPOSE SEWER DRAIN PIPE. (2) LARGE CRACK ABOVE MIRROR APPROX 3' LONG EXTENDED UP TOWARDS CEILING & APPROX 3 LONG. (3) 2' DOOR CONNECTS BOTH KITCHENS. FLOORING: (1) SEVERAL FLOOR TILES APPROX 34 TILES ARE CRACKED & BROKEN. 240-6764 - MANNY(SON) / NORMA. UNIT A- ELECTRICAL: (1) INTERIOR SUB PANEL LOCATED IN KITCHEN, LACKS BRANCH CIRCUIT DESIGNATION. (2) SEVERAL RECEPTACLES WERE TESTED (3 PRONG) & WERE LACKING MECHANICAL GROUNDS. (3) EXPOSED ELECTRICAL CONDUCTOR IN JUNCTION BOX LACKING COVER PLATE IN SW BEDROOM & 3 PRONG RECEPTACLES LACKING COVER PLATE. (4) BATHROOM LIGHT FIXTURE HAS UNGROUND 2 PRONG RECEPTACLE. MECHANICAL: (1) FURNACE HAS BEEN TAG BY S.W. AS INOPERABLE, GAS VALVE COMPARTMENT IS FULL OF LINT & DUST, REQUIRE SERVICING. PLUMBING: (1) LAVE SINK HAS DETACHED FROM WALL. (2) P-TRAP IS BROKEN. (3) ANGLE STOP IS LEAKING & HAS NO SHUT OFF HANDLE. (4) TOILET SEAT IS BROKEN & CRACKED. (5) EXTERIOR CLEAN OUT LACKS CAP. INTERIOR FEATURES: (1) BATHROOM WALL & CEILING SHOW WATER DAMAGE, PAINT HAS BLISTERED, CRACKED & PEELING AWAY. (2) SEVERAL TILES BROKEN & CRACKED. STRUCTURAL W/O/P: (1) WALL HAS BEEN ADDED W/ ELECTRICAL, UNIT WAS A ONE TIME EFFICIENCY APT, WALL HAS BEEN ADDED TO CREATE BEDROOM. ACCESS CONTROL: (1) SOUTHWEST BEDROOM WINDOW CRANK DOSE NOT WORK (CLOSE), SCREEN MUST BE REMOVED BEFORE CLOSING.
12/30/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE & MEET WITH OWNER ON FW/UP INSPECTION. WENT OVER N.O.V. ISSUE. OWNER HAS DECIDED TO RETURN STRUCTURE TO SINGLE FAMILY DWELLING. PLANS ARE TO REMOVE ILLEGALLY INSTALLED INTERIOR WALL & KITCHEN, KITCHEN WILL BECOME LAUNDRY ROOM. ALTERNATIVE HOT WATER SYSTEM INSTALL WILL HANDLE SINGLE FAMILY HOT WATER NEEDS, HOWEVER PERMIT WILL STILL BE REQUIRED FOR ALTERATION TO ORIGINAL GAS PIPING SYSTEM. OWNER IN PROGRESS OF ACQUIRING ELECTRICAL & HEATING CONTRACTORS FOR ELECTRICAL UP-GRADE & INSTALLATION OF NEW WALL FURNACE. BOTH UNITS ARE VACANT & SECURED AT THIS TIME & FLOORING FOR UNIT B HAS BEEN REPLACED WITH CERAMIC TILE. ADDITION OF STORAGE STRUCTURE LOCATED ON EAST END OF STRUCTURE WILL BE REMOVED. ZONING HAS CONTACTED NEIGHBOR ON EASTSIDE & IS WORKING OUT DETAILS FOR FIRE WALL WITH RICHARD DIAZ. WILL DO FW/UP IN 45 DAYS.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00797
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
10/15/2004 CONTACTED BY PHONE
04/12/2005 CONTACTED BY MAILING
11/08/2004 NOTICE OF VIOLATION ISSUED
11/08/2004 COURT ORDERED ABATEMENT
07/15/2005 VIOLATION CLOSED
10/18/2004 RESEARCH AT DSD