Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE ON FW/UP INSPECTION, OWNER MADE ARRANGEMENTS TO LEAVE DOOR OPEN & DNR INSPECTOR TO SECURE WHEN INSP. IS COMPLETE . SOME VIOLATION HAD BEEN PREVIOUSLY ABATED ON EALIER INSP. 1) T.C. SEC.16-11E 3 & 4 PLUMBING SYSTEM ABATED- CAP INSTALLED & SECURED 2) T.C. SEC.16-11 E 3 & 4 PLUMBING SYS. ABATED- NEW SINK INSTALLED 3) T.C. SEC.16-11 E 3 & 4 PLUMBING SYS. ABATED- NEW TOLIET IS INSTALLED 4) T.C. SEC.16-11 E 3 & 4 PLUMBING SYS. ABATED- NEW ANGLE STOP INSTALLED 5) T.C. SEC.16-11 B 1 HEATING SYS. D MECHNICAL SYS. ABATED- VIOLATION WAS REMOVED, HEATER WAS REMOVED 6) T.C. SEC.16-11 BUILDING INTERIORS F INTERIOR FEATURES 1 & 2 NOT ABATED- WALL PATCHED BUT LACKS FINISHING (PAINT) 7) T.C. SEC 16-11 BUILDING INTERIOR F INTERIOR FEATURES NOT ABATED- SOME BROKEN DENT SPILT TILES REMAIN 8) T.C. SEC.16-11 BUILDING & INTERIORS J ACCESS CONTROL 2 ABATED- NEWE CLOSING HARDWARE INSTALLLED 7-1-05 9) T.C. SEC.16-12 BUILDING & STRUCTURE EXTERIOR A EXTERIOR SURFACES ABATED- NEW WINDOWS INSTALLED. 10) T.C. SEC.16-12 BUILDING & STRUCTURE EXTERIOR A EXTERIOR SURFACES 1 ABATED- NEW WEATHER STRIPPING INSTALLED 11) T.C. SEC.16-12 BUILDING INTERIOR J ACCESS CONTROL 2 ABATED- NEW CLOSING HARDWARE INSTALLED 7-1-05 12) T.C. SEC.16-11 B 1 HEATING SYS. D MEHNICAL SYS. ABATED- GAS VALUE COMPARTMENT HAS BEE CLEANED 13) T.C. SEC.16-11 BUILDING INTERIOR A FIRE SAFETY ABATED- NEW SMOKE DETECTORS INSTALLED 14) T.C. SEC.16-11 BUILDING INTERIOR F INTERIOR FEATURES 1 &2 NOT ABATED- LACKING FINISHING (PAINT) 15) T.C. SEC.16-4 PERMITS & T.C. SEC.16-11 E 3 & 4 PLUMBING SYS. ABATED- PERMIT # T05PL00803- FINALED 5-2-05 16) T.C. SEC.16-4 PERMITS REQUIRED T.C. SEC 16-11 BUILDING INTERIOR C ELEC. SYS. 1 & 2 ABATED- NEW SERVICE INSTALLED 100 AMPS PERMIT # T05EL00528 FINALED 3-18-05 17) T.C. SEC.16-4 PERMITS REQUIRED NOT ABATED- DRAWING FOR WALLS ADDITION HAVE NOT BEEN SUBMITTED. SPOKE WITH OWNER STATED HE WILL REMOVE 4' OF WALL TO MAKE INTO PORTIONS, PORTION DO NOT REQUIRE PERMIT & SHOULD BE COMPLETED BY 7-15-05. OWNER WILL CONTACT DNR INSPECTOR WHEN COMPLETED. NO PICTURES WERE TAKEN. IF NOT COMPLETE BY 7-15-05 CITATION WIL BE ISSUED. 3 |
|
| 03/30/2005 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | ARRIVED ON SITE, MET WITH OWNER, ANDY WALKED INTERIOR OF HOUSE. CHECK MAIN SERVICE ON EXTERIOR OF STRUCTURE, FOUND THAT NEW ELECTRICAL SERVICE HAD BEEN INSTALLED TO THE MIDDLE REAR OF STRUCTURE AND WAITING FOR NEW OVERHEAD SERVICE FROM TEP. (POWER TEMPORARILY BACK FED FROM EXISTING UNDERGROUND SERVICE.) 2. TC16-11 - SEWER CAPPED INSTALLED VIOLATION ABATED. 3. TC16-11 E 3&4 - SINK PROPERLY MOUNTED, P-TRAP REPAIRED, AND TOILET REPAIRS (ANGLE STEP LEAKING) COMPLETED. 4. TC 16-11 E 3&4 - TOILET SEAT INSTALLED ITEM ABATED. 5. HEATING SYSTEM NOT FIXED ITEM UNABATED. 6. 16-11 F3 3150-A - INTERIOR FIXTURES UNABATED, NOT TAPED TEXTRUED OR PAINTED. 7. 16-11F3 - FLOORING REPLACED WITH CERAMIC TILE ITEM ABATED. 8. 16-112 - NOT ABATED. 9. 16-12 - EXTERIOR SURFACES NOT ABATED SOLAR WINDOWS NOT REPLACED. 10. 16-112 - NOT ABATED. 11. 16-11 12 UNABATED. 12. 16- HEATING SYSTEM UNABATED. 13. ABATED. 14. 16-11 F 1& 2 - NOT COMPLETED ORIGINAL PATCH MADE FINISH INCOMPLETE. 15. UNABATED OWNER HAS ARRANGED FOR CONTRACTOR TO DO REPAIRS. 16. 16-4 - PERMITS REQUIRED. UNABATED WORK IN PROGRESS WAITING TEP DROP AND INSPECTION. |
|
| 12/30/2004 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE & MEET WITH OWNER ON FW/UP INSPECTION. WENT OVER N.O.V. ISSUE. OWNER HAS DECIDED TO RETURN STRUCTURE TO SINGLE FAMILY DWELLING. PLANS ARE TO REMOVE ILLEGALLY INSTALLED INTERIOR WALL & KITCHEN, KITCHEN WILL BECOME LAUNDRY ROOM. ALTERNATIVE HOT WATER SYSTEM INSTALL WILL HANDLE SINGLE FAMILY HOT WATER NEEDS, HOWEVER PERMIT WILL STILL BE REQUIRED FOR ALTERATION TO ORIGINAL GAS PIPING SYSTEM. OWNER IN PROGRESS OF ACQUIRING ELECTRICAL & HEATING CONTRACTORS FOR ELECTRICAL UP-GRADE & INSTALLATION OF NEW WALL FURNACE. BOTH UNITS ARE VACANT & SECURED AT THIS TIME & FLOORING FOR UNIT B HAS BEEN REPLACED WITH CERAMIC TILE. ADDITION OF STORAGE STRUCTURE LOCATED ON EAST END OF STRUCTURE WILL BE REMOVED. ZONING HAS CONTACTED NEIGHBOR ON EASTSIDE & IS WORKING OUT DETAILS FOR FIRE WALL WITH RICHARD DIAZ. WILL DO FW/UP IN 45 DAYS. |