Case: T04DV00797

Parcel: 130101670


Addresses:

3150 E 26TH ST

Inspection Status: Violation

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/30/2005 INSP - INITIAL CODE ENFORCMENT Violation 40 % ABATEMENT
VISITED SITE, PRESENT WERE DNR INSPECTORS H.LOPEZ, G.GOODMAN & OWNER ANDY NG. WALKED PROPERTY TO DETERMIN ISSUES IN COMPLAINCE.
(1) TC SEC.16-11 (E3 & 4) PLUMBING SYS.
UNIT 3150 A
ABATED
NEW SEWER CAP INSTALLED
(2) ABATED
NEW ATTACHING HARDWARE HAS BEEN INSTALLED FOR SINK & REMOUNTED TO WALL.
(3) ABATED
NEW ANGLE STOP VALE INSTALLED.
(4) ABATED
NEW TIOLET SEAT INSTALLED.
(5) TC 16-11 (B 1) HEATING SYS. (D) MECH. EQUIPMENT
UNIT 3150 A, NOT ABATED
HAVING PROBLEMS AQUIRING QUIFIED TECH. TO DO REPAIRS.
(6) TC SEC 16-11 BUILDING INTER. (F) INTERIOR FEATURES 1&2
UNIT 3150 A NOT ABATED.
(7) TC SEC 16-11 BUILDING INTER. (F) INTERIOR FEATURES (3)
UNIT 3150 A, ABATED
NEW CERAMIC TILE INSTALLED.
(8) TC SEC 16-11 BUILDING INTER. (J) ACCESS CONTROL (2) UNIT 3150 A, NOT ABATED
(9) TC SEC 16-12 BUILDING & STRUCTURES EXTERIOR (A) EXTERIOR SURFACES (1) WEATHER PROTECTION.
UNIT 3150 (B) NOT ABATED
NO PROGRESS MADE ON WINDOWS
(10) TC SEC 16-12 BUILDING & STRUCTURES EXTERIOR (A) EXTERIOR SURFACES (1) WEATHER PROTECTION.
UNIT 3150 (B) NOT ABATED
NO PROGRESS MADE ON DOOR
(11) TC SEC 16-11 BUILDING INTER. (J) ACCESS CONTROL (2)
UNIT 3150 (B) NOT ABATED
NO PROGRESS ON WINDOW CRANKS.
(12) TC 16-11 (B 1) HEATING SYS. (D) MECH. EQUIPMENT
UNIT 3150 B, NOT ABATED,
HAVING PROBLEMS AQUIRING QUIFIED TECH. TO DO REPAIRS.
(13) TC SEC 16-11 BUILDING INTER. (A) FIRE SAFETY (3) UNIT 3150 B, ABATED
NEW SMOKE DETECTOR INSTALLED
(14) TC SEC 16-11 BUILDING INTER. (F) INTER. FEATURES 1&2
UNIT 3150 B, NOT ABATED. 8O% COMPLETED
(15) TC SEC 4 PERMITS REQUIRED
TC SEC.16-11 (E3 & 4) PLUMBING SYS.
UNIT 3150 B, NOT ABATED.
OWNER HAS ARRANGED FOR CONTRACTOR TO DO REPAIRS.
(16) TC SEC 4 PERMITS REQUIRED, TC 16-11 BUILDING INTER. (C) ELECTRICAL SYS. (1&2)
UNITS 3150 A&B,
NOT ABATED, CONTRACTOR WORKING ON ABATING ISSUE, NEW SERVICE UP-GRADE IS AWATING FINLE FOR TEP RECONNECT.
(17) TC SEC 4 PERMITS REQUIRED
UNITS 3150 A&B
NOT ABATED, CONTRACTOR HAS BEEN HIRED.
PICTURES WERE TAKEN. WILL CONFER WITH INSP.II RICK SALDATE CONCERNING MORE TIME TO ABATE ISSUE REQUESTED BY OWNER.
10/06/2004 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE INITIAL INSPECTION WAS DONE ON UNIT B, PRESENT WERE TENANTS & DNR INSP. VIOLATION ARE AS FOLLOWS.
ELECTRICAL W/O/P:
(1) ADDITION & ALTERATION TO ORIGINAL ELECTRICAL SYSTEM HAVE BEEN DONE. OUTSIDE ELECTRICAL DISCONNECT HAS BEEN REMOVED 1 1/2 GALVANIZED PIPE CONTACTING ELECTRICAL CONDUCTORS, RUNS FROM T.E.P. METER DOWN INTO GROUND. SUB PANEL IS IN UNIT A. UNIT HAS NO EMERGENCY SHUT OFF (DISCONNECT) IN CASE OF EMERGENCY. ELECTRICAL ALTERATION HAVE BEEN DONE IN A HAZARDOUS MANNER.
(2) TEST EQUIPMENT WAS USED ON 3 SPRONG RECEPTACLES & WERE FOUND LACKING MECHANICAL GROUND.
(3) NO GFIC IN KITCHEN.
(4) ELECTRICAL SYSTEM IS A TWO WIRE SYSTEM, WILL REQUIRE DEADICATED CIRCUITS FOR KITCHEN RECEPTACLES W/ GFIC & 1 FOR REFRIGERATOR & ELECTRICAL UPGRADE.
(5) NO GFIC IN BATHROOM.
ORIGINAL 60 AMP SERVICE IS MOUNTED ON TOWER POLE, ELECTRICAL DISCONNECT IN A DETERIORATED & DELAPATATED STATE, LARGE AMOUNTS OF RUST & ELECTRICAL CONDUCTOR HAVE BEGUN TO CRACK.
WEATHER PROOFING:
(1) SEVERAL BROKEN WINDOWS THROUGH OUT STRUCTURE.
(2) ENTRY DOOR REQUIRES ADJUSTMENT OF WEATHER STRIPPING.
ACCESS CONTROL:
(1) BATHROOM WINDOW CRANKS NOT WORKING.
(2) NORTHEAST BEDROOM CRANK NOT WORKING.
HEATING:
(1) FURNACE REQUIRES SERVICING.
PLUMBING:
(1) ORIGINAL GAS PIPING HAS BEEN ALTERED, ADDITION OF GAS PIPING FOR NEW WALL MOUNTED HOT WATER HEATER BOSCH TYP-MAY BE 5 GAL. ONLY & OPERATES FOR BOTH A & B UNITS.
(2) ADDITION OF WATER LINES W/ NEW METAL BRAIDED LINES, ORIGINAL HOT WATER HEATER HAS BEEN REMOVED.
(3) SHUT OF FOR STOVE IS NOT READY ACCESSABLE, STOVE HAS TO BE PULLED OUT & REACH IN & AROUND CORNER CABINET.
(4) POSSABLE WRONG APPLICATION OF HOT WATER HEATER IN KITCHEN, CHECK W/ PLUMBING INSP.
(5) INCORRECT INSTALLATION OF SHUT OFF VALVE & HANDLE IS BROKEN.
STRUCTURAL:
(1) NEW WALL HAS BEEN ERECTED, INFORMATION FROM PREVIOUS OWNER NEXT DOOR VERIFIED ROOM HAS BEEN SPLIT, WALL HAS NO ELECTRICAL.
FIRE PROTECTION:
(1) LACKING REQUIRED WORKING SMOKE DETECTOR.
INTERIOR FEATURES:
(1) LARGE HOLE UNDER SINK PEDISTAL, EXPOSE SEWER DRAIN PIPE.
(2) LARGE CRACK ABOVE MIRROR APPROX 3' LONG EXTENDED UP TOWARDS CEILING & APPROX 3 LONG.
(3) 2' DOOR CONNECTS BOTH KITCHENS.
FLOORING:
(1) SEVERAL FLOOR TILES APPROX 34 TILES ARE CRACKED & BROKEN.
240-6764 - MANNY(SON) / NORMA.
UNIT A-
ELECTRICAL:
(1) INTERIOR SUB PANEL LOCATED IN KITCHEN, LACKS BRANCH CIRCUIT DESIGNATION.
(2) SEVERAL RECEPTACLES WERE TESTED (3 PRONG) & WERE LACKING MECHANICAL GROUNDS.
(3) EXPOSED ELECTRICAL CONDUCTOR IN JUNCTION BOX LACKING COVER PLATE IN SW BEDROOM & 3 PRONG RECEPTACLES LACKING COVER PLATE.
(4) BATHROOM LIGHT FIXTURE HAS UNGROUND 2 PRONG RECEPTACLE.
MECHANICAL:
(1) FURNACE HAS BEEN TAG BY S.W. AS INOPERABLE, GAS VALVE COMPARTMENT IS FULL OF LINT & DUST, REQUIRE SERVICING.
PLUMBING:
(1) LAVE SINK HAS DETACHED FROM WALL.
(2) P-TRAP IS BROKEN.
(3) ANGLE STOP IS LEAKING & HAS NO SHUT OFF HANDLE.
(4) TOILET SEAT IS BROKEN & CRACKED.
(5) EXTERIOR CLEAN OUT LACKS CAP.
INTERIOR FEATURES:
(1) BATHROOM WALL & CEILING SHOW WATER DAMAGE, PAINT HAS BLISTERED, CRACKED & PEELING AWAY.
(2) SEVERAL TILES BROKEN & CRACKED.
STRUCTURAL W/O/P:
(1) WALL HAS BEEN ADDED W/ ELECTRICAL, UNIT WAS A ONE TIME EFFICIENCY APT, WALL HAS BEEN ADDED TO CREATE BEDROOM.
ACCESS CONTROL:
(1) SOUTHWEST BEDROOM WINDOW CRANK DOSE NOT WORK (CLOSE), SCREEN MUST BE REMOVED BEFORE CLOSING.
10/04/2004 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, MADE CONTACT WITH TENANT FROM UNIT A. ASKED TENANT IF ANYONE WAS HOME AT UNIT B. TENANT STATED, TENANT'S STATED TENANT'S FROM UNIT B ARE IN AND OUT. TENANTS ARE RELATED (AUNT & NEPHEW). TENANT FROM UNIT A STATED THEY HAD ISSUES THEY WANTED TO REPORT. WALKED STRUCTURE INTERIOR AND FRONT YARD. MIN HOUSING VIOLATIONS WERE FOUND
PLUMBING
1. EXTERIOR SEWER CLEANOUT MISSING CP.
2. BATHROOM SINK HAS DETACHED FROM WALL AND PLUMBING WATEARM BROKEN, ANGLE STOP HAS NO HANDLE TO SHUT OFF WATER.
ELECTRICAL
1. LIVING ROOM WALL HAS MISSING COVER PLATE IN BEDROOM, APPEARS WALL HAS BEEN BOOTED IN, EXISTING RECEPTACLES ARE 2 WIRE AND LIVING ROOM WALL AND BEDROOM WALL HAVE 3 PRONG RECEPTACLES. EVIDENCE SHOWING UNIT HAS BEEN ILLEGALLY SPLIT ARE.
1. INTERIOR SUBPANEL FOR BOTH UNITS A & B ARE IN KITCHEN WALL IN UNIT A. TENANT STATED WHEN BOTH UNITS ARE USING MICROWAVE SUBPANEL BREAKERS TRIP.
2. ENTRY DOOR TO UNIT B IS IN KITCHEN OF UNIT A NEXT TO STOVE.
3. ZONING VIOLATION W/O/P ADDITION OF STORAGE SHED TO PROPERTY LINE.
4. INTERIOR WALL FOR BEDROOM AND LIVING BUTTS UP AGAINST WALL FURNACE. WALL FURNACE COVER HAS BEEN MODIFIED TO ALLOW ROOM FOR ATTACHING WALL. GAVE CONTACT NUMBER FOR DNR AND REQUESTED CONTACT WITH TENANT BE MADE FROM UNIT B FOR INSPECTION OF INTERIOR AND BACK YARD. NO ENTRY INTO BACK YARD. NO ENTRY INTO BACK YARD UNLESS DONE THROUGH UNIT B.
NEXT DOOR NEIGHBORHODD AT 3158 HAS BUILT A POSSIBLE AZ ROOM AND SHED/CARPORT TO WEST PROPERTY LINE, REFERRAL WILL BE MADE TO ZONING. AZ ROOM WITH ELECTRICAL.