Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

06/10/2004

Applicant:

ECKHARDT ERNEST OTTO & EDITH JT/

Description:

COMPLAINT:MIN HOUSING- KITCHEN TILE COMING APART. 3 BROKEN WINDOWS, FRONT DOOR DOES NOT FIT FRAME. BACK DOOR DOESN'T CLOSE RIGHT. ABOVE STOVE HAS LOOSE WIRES HANGING WHERE VENT GOES. KITCHEN CABINETS FALLING APART. BATHROOM & KITCHEN SINK CLOGGED. ROOF LEAKS IN (2) PLACES WHEN IT RAINS.

Outstanding Inspections

Case Number: T04DV00501
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
NPO - UNSECURED BUILD OR STRUC None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
NPO(DL)-DILAPIDATED STRUCTURE None Not Inspected
NPO(DL)-VACANT & UNSEC.STRUCT None Not Inspected
10/29/2004 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 10/29/04, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT KRYSTAL, WHO SHOWED ME AROUND, INSP. SHOWS FRONT DOOR LACKS PROPER WEATHER PROTECTION. FRONT DOOR LOCK DOES NOT OPERATE AS INTENDED. ALL OF LIVING ROOM WINDOW LOCKS ARE BROKEN. 1 LIVING ROOM WINDOW BROKEN. KITCHEN FLOOR TILE PEELING UP FROM FLOOR, TILES MISSING, TILES CHIPPED AND BROKEN. KITCHEN CEILING LEAKS WHEN IT RAINS. DRYWLL HAS BEEN REPLACED WITH NO PROTECTIVE COVERINGS HAS BEEN INSTALLED AND DOES NOT SIT FLUSH WITH OTHER CEILING. ALSO LEAKS INSIDE OF KITCHEN CABINETS ABOVE SINK. DRYWALL FALLING AND DETERIORATED. CABINET DETERIORATING AND COMING APART AT BOTTOM. RANGE HOOD AT COOK STOVE HAS EXPOSED ELECTRICAL WIRING. CONVENIENCE OUTLET BY SINK HAS BROKEN COVER PLATE, NOT GFCI PROTECTED. LIVING ROOM FLOOR DETERIORATING TO A POINT OF PLYWOOD IS WEAK AND SPONGY, LIFTING AND SEPERATING, BY FRONT DOOR CAN SEE ALL THE WAY THROUGH TO GROUND. KITCHEN TO HALLWAY FLOOR IS DETERIORATING BY WALL, WEAK AND SPONGY HAS DROP FROM KITCHEN FLOOR TO HALLWAY FLOOR. DWELLING LACKS SMOKE DETECTOR. EXPOSED ELECTRICAL WIRING IN FURNACE ROOM, ADDED HALL LIGHT SWITCH, RESIDENT STATES THAT HEATER HAS NEVER WORK, HEATER LACKS MAINTENANCE, SQUIRREL CAGE HAS BUILD UP ON FINS, MOTOR HAS BUILD UP OF DIRT, COB WEBS HANGING INSIDE AND OUT. BEDROOM 1 HAS BEEN DRYWALLED OVER EXSITING WALL CONVENIENCE OUTLET SITS IN WALL HARD TO REACH. BATHROOM HAS BEEN INSTALLED WHERE CLOSET USED TO BE. LIGHT FIXTURE MISSING PROTECTIVE COVERING. HALLWALL COOLER SWITCH MISSING COVER PLACT. HEATER THERMOSTAT LOCATED IN WRONG AREA, LOCATER BY BACK DOOR AND OUTSIDE WALL, HALLWAY FLOOR UNEVEN IN FRONT OF BATHROOM DOOR. BATHROOM NOT GFCI PROTECTED. BATHROOM WINDOW FRAME DETERIORATING AND FALLING APART. BATHROOM CELING LEAKS. WHEN IT RAINS WATER COMES DOWN WALL IN SHOWER AREA. BEDROOM WINDOW BROKEN. CONVENIENCE OUTLET WEST WALL WORN TO A POINT OF HAVING TO WIGGLE PLUG TO MAKE WORK. BEDROOM DOOR OF HINGES AND LAYING UP AGINST WALL. CLOSET DOORS DO NOT OPERATE DUE TO BEING OFF TRACK. EXTERIOR FENCING DETERIORATED ALL AROUND PROPERTY, LISTING AND LEANING OUT WARD, FALLING DOWN, AND MISSING IN AREAS. STAIRS ON SOUTH SIDE LACKS HAND RAILS. 2 STEP DETERIORATED. NORTH SIDE KITCHEN WINDOW HAS BEEN REPLACE WITH DIFFERENT ONE, HAS NOT BEEN PROPERLY INSTALLED.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00501
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
02/28/2005 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved 2/25/05 CALLED LANIER REALTY PRIOR TO INSPECTION TO FIND OUT IF UNITS HAD BEEN SECURED. THERE WAS NO ANSWER AND NO RETURN CALL. REVISITED SITE, TOOK PICTURES, FINDINGS ARE AS FOLLOWS: SHED: PLYWOOD ON SHED HAD ALL BEEN PROPERLY SECURED. UNIT 1711: ALL WINDOWS AND DOORS HAD BEEN SECURED UNIT 1705: ALL WINDOWS AND DOORS HAD BEEN PROPERLY SECURED. UNITS 1701 A,B,C: ALL THREE UNITS PROPERLY SECURED. COMPLAINCE/ CASE CLOSED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00501
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
10/18/2004 CONTACTED BY PHONE
11/04/2004 NOTICE OF VIOLATION ISSUED
11/04/2004 COURT ORDERED ABATEMENT
03/01/2005 VIOLATION CLOSED