Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T04DV00501

Parcel: 11941248C


Addresses:

1701 W AJO WY #C


Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00501

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Correction Required

Date Description Inspector Results Comments
10/29/2004 INSP - INITIAL CODE ENFORCMENT Correction Required 10/29/04, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT KRYSTAL, WHO SHOWED ME AROUND, INSP. SHOWS FRONT DOOR LACKS PROPER WEATHER PROTECTION. FRONT DOOR LOCK DOES NOT OPERATE AS INTENDED. ALL OF LIVING ROOM WINDOW LOCKS ARE BROKEN. 1 LIVING ROOM WINDOW BROKEN. KITCHEN FLOOR TILE PEELING UP FROM FLOOR, TILES MISSING, TILES CHIPPED AND BROKEN. KITCHEN CEILING LEAKS WHEN IT RAINS. DRYWLL HAS BEEN REPLACED WITH NO PROTECTIVE COVERINGS HAS BEEN INSTALLED AND DOES NOT SIT FLUSH WITH OTHER CEILING. ALSO LEAKS INSIDE OF KITCHEN CABINETS ABOVE SINK. DRYWALL FALLING AND DETERIORATED. CABINET DETERIORATING AND COMING APART AT BOTTOM. RANGE HOOD AT COOK STOVE HAS EXPOSED ELECTRICAL WIRING. CONVENIENCE OUTLET BY SINK HAS BROKEN COVER PLATE, NOT GFCI PROTECTED. LIVING ROOM FLOOR DETERIORATING TO A POINT OF PLYWOOD IS WEAK AND SPONGY, LIFTING AND SEPERATING, BY FRONT DOOR CAN SEE ALL THE WAY THROUGH TO GROUND. KITCHEN TO HALLWAY FLOOR IS DETERIORATING BY WALL, WEAK AND SPONGY HAS DROP FROM KITCHEN FLOOR TO HALLWAY FLOOR. DWELLING LACKS SMOKE DETECTOR. EXPOSED ELECTRICAL WIRING IN FURNACE ROOM, ADDED HALL LIGHT SWITCH, RESIDENT STATES THAT HEATER HAS NEVER WORK, HEATER LACKS MAINTENANCE, SQUIRREL CAGE HAS BUILD UP ON FINS, MOTOR HAS BUILD UP OF DIRT, COB WEBS HANGING INSIDE AND OUT. BEDROOM 1 HAS BEEN DRYWALLED OVER EXSITING WALL CONVENIENCE OUTLET SITS IN WALL HARD TO REACH. BATHROOM HAS BEEN INSTALLED WHERE CLOSET USED TO BE. LIGHT FIXTURE MISSING PROTECTIVE COVERING. HALLWALL COOLER SWITCH MISSING COVER PLACT. HEATER THERMOSTAT LOCATED IN WRONG AREA, LOCATER BY BACK DOOR AND OUTSIDE WALL, HALLWAY FLOOR UNEVEN IN FRONT OF BATHROOM DOOR. BATHROOM NOT GFCI PROTECTED. BATHROOM WINDOW FRAME DETERIORATING AND FALLING APART. BATHROOM CELING LEAKS. WHEN IT RAINS WATER COMES DOWN WALL IN SHOWER AREA. BEDROOM WINDOW BROKEN. CONVENIENCE OUTLET WEST WALL WORN TO A POINT OF HAVING TO WIGGLE PLUG TO MAKE WORK. BEDROOM DOOR OF HINGES AND LAYING UP AGINST WALL. CLOSET DOORS DO NOT OPERATE DUE TO BEING OFF TRACK. EXTERIOR FENCING DETERIORATED ALL AROUND PROPERTY, LISTING AND LEANING OUT WARD, FALLING DOWN, AND MISSING IN AREAS. STAIRS ON SOUTH SIDE LACKS HAND RAILS. 2 STEP DETERIORATED. NORTH SIDE KITCHEN WINDOW HAS BEEN REPLACE WITH DIFFERENT ONE, HAS NOT BEEN PROPERLY INSTALLED.
10/28/2004 INSP - INITIAL CODE ENFORCMENT Correction Required 10/28/04, VISITED SITE, ONLY ONE HOME IS A 14 YR OLD SON, ABRAHAM, TALKED WITH ABRAHAM FOR A MINUTE ABOUT SOME OF THE ISSUES AND HE STATED YES THAT REPAIRS NEEDED, I LEFT MY CARD WITH HIM WITH CELL NUMBER FOR CONTACT, STATED HIS MOTHER SHOULD BE HOME ABOUT 1-2, TOLD ABRAHAM TO HAVE HIS MOTHER CALL ME, HE AGREED.