Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

03/11/2004

Applicant:

RCS ENGINEERING INC

Description:

COMPLAINT:MIN HOUSING-SEWAGE COMING OUT OF CLEAN-OUTS IN BACK YARD. ROACHES

Outstanding Inspections

Case Number: T04DV00214
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
03/25/2004 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 3/18/04, VISITED PROPERTY, TOOK PICTURES, WALKED COMPLETE EXTERIOR OF PROPERTY, FOUND ISSUES IN NEED OF REPAIR, FRONT PART OF STRUCTURE, OFFICE, STRUCTURE BRICKS SEPERATING AND HAS MOVED, HAS EXPOSED ELECTRICALAT CONVENIENCE OUTLET, 2ND DOOR DETERIORATED COMMING APART, UNIT SHOWS BED, CLOTHES, LOOKS OCCUPIED IN UNIT, CONVENIENCE OUTLET ON EXTERIOR NOT WEATHER PROTECTED, PAINT ON EXTERIOR PEELING AND CHIPPING AWAY, GROUNDSMAN MIKE HICKEY WAS HIRED TO DO CLEAN UP OF GROUNDS ON PROPERTY, ALSO LIVES IN ONE OF THE UNITS, LAUNDRY AREA HAS BEEN INSTALLED WHERE 2 CARPORTS WERE DESIGNATED, ROOF HAS BEEN INSTALLED OUT OF 2"X4" AND SPANDS APPOX. 10', ELECTRICAL CIRCUITS HAS BEEN ADDED FOR WASHERS AND DRYERS, OPEN AND EXPOSED WIRING, ELECTRICAL SERVICE HAS BEEN DOUBLED LUGGED TO SUPPY THIS ELECTRICAL SERVICE TO EQUIPMENT, NONE OF WHICH IS GFCI PROTECTED, 1 LINE TO WASHER, ONE TO DRYER, ANOTHER TO JUNCTION BOX UP AT TOP, HAS HAD LIGHTS INSTALLED ALSO, SHOP LIGHTS, (FLOURESENT) THIS TYPE OF INSTALLATION WOULD NOT PASS INSPECTION, THEREFORE I DO NOT BELIVE ANY PERMITS HAS BEEN SECURED FOR ROOF OR ELECTRICAL CIRCUIT ADDITIONS. UNIT 1 HAS BROKEN WINDOW IN REAR OF STRUCTURE. UNIT 2 HAS EXPOSED ELECTRICAL WIRING IN REAR OF STRUCTURE, COOLER LEAKING ON TO GROUND ALLOWING WATER TO STAND AND PUDDLE. UNIT 3 ADDED CONVENIENCE OUTLET, NOT WEATHER PROTECTED NOR GFCI PROTECTED. UNIT 4 ELECTRICAL SERVICE IN CARPORT MISSING COVER, ALSO SHOWING DOUBLE LUGGING IN PANEL BOX, ELOECTRIC BOX IN REAR OF STRUCTURE HAS EXPOSED WIRING, ADDED CONVENIENCE OUTLET IN STALLED NOT WEATHER PROTECTED OR GFCI PROTECTED, HOT WATER TANK MISSING PRESSURE RELIEF VALVE DRAIN LINE. UNIT 5 MORTOR MISSING IN BETWEEN BRICKS, PAINT PEELING AND CHIPPING AWAY, UNIT 6 ELECTRIC SERVICE PANEL IN CARPORT SHOWING DOUBLE LUGGING ON 2 BREAKERS, ADDED ELECTRICAL CIRCUITS, WEATHER PROTECTED BOX MISSING COVERS, UNIT 7 ADDED ELECTRICAL CIRCUIT CONVENIENCE OUTLET, LIGHT BULB BROKEN WITH FILAMENT HANGING LOOSE, EXPOSED WIRING, FRONT DOOR JAMB HAS BEEN REPLACED BUT NOT FINISHED, RAW WOOD EXPOSED, NO SEALANT, MORTOR MISSING FROM IN BETWEEN BRICKS, REAR WINDOW BROKEN. UNIT 8 BROKEN LIGHT BULB IN FIXTURE, MORTOR MISSING FROM IN BETWEEN BRICKS, PAINT PEELING AND CHIPPING AWAY, COOLER LEAKING ON TO GROUND AND ALLOWING WATER TO STAND AND PUDDLE, TELEPHONE BOX LAYING ON GROUND, NOT SECURED TO STRUCTURE, ELECTRIC BOX MISSING DEAD PLATE, HAS WROUGHT IRON SECURITY BARS INSTALLED NOT OF BREAK AWAY TYPE IN CASE OF FIRE OR PANIC. UNIT 9 ELECTRIC CIRCUIT ADDED, HOT WATER TANK PRESSURE RELIEF VALVE DRAIN LINE NOT INSTALLED, BATH WINDOW BROKEN, UNIT 10 ADDED ELECTRICAL CIRCUIT, GFCI CONVENIENCE OPUTLET, 2 WINDOWS BROKEN, STRUCTURE SHOWS CRACKS, UNIT 11 EXPOSED ELECTRICAL WIRING, KNOCK OUT PLUG MISSING AT BOX, CONVENIENCE OUTLET BURNT NOT WEATHER PROTECTED, UNIT 12 NEW HOT WATER TANK HAS BEEN INSTALLED, RESEARCH FOR PERMIT. UNIT 14 NEW HOT WATER TANK INSTALLED, RESEARCH FOR PERMIT. UNIT 15 ELECTRIC SERVICE PANEL SHOWS DOUBLE LUGGING ON 2 SEPERATE BREAKERS, UNIT 16 HAS BROKEN WINDOW UNIT 17 ADDED ELECTRICAL CIRCUITS WHICH GO DIRECTLY INTO INTERIOR OF UNIT, PAINT ON WALLS AND FACIA MISSING, ALL OF PROPERTY HAS PAINT PEELING AND CHIPPING AWAY, IN NEED OF PROTECTIVE COATING. POOL AREA POOL AREA HAS FENCING AROUND POOL, GATE IN NEED OF REPAIR, SUPPORT POST AT GATE IN NEED OF REPAIR, SOME AREA HAS OPENING LARGER THAN 4", POOL HOLDING SOME RAIN WATER, APPOX 2-3 FEET, HAS TURNED DARK.
04/08/2005 VIOL(EL) - OTHER JORTA Correction Required MET WITH PART OWNER OF "EL SOL MOTEL" MR. BOB STEWART, AS HE WAS EXPECTING ME TO HAND DELIVER A SUPPLEMENTAL" NOTICE AND ORDER". A CHANGE IN THE DOCUMENTS AND TIME CONSTRAINTS HAD OCCURED DUE TO AN ASSUMPTION OF THE VIOLATION FROM THE LEASEE/BUYER, BACK TO THE STEWART'S ie. R.C.S. ENGINEERING. I HANDED MR. STEWART A COPY OF THE NEW NOTICE AND ORDER AND READ VERBATIM THE CONTENTS OF THE SUPPLEMENTAL NOTICE AND ORDER. I ACCENTUATED TO MR. STEWART THE NEW TIME CONSTRAINTS AND RELEGATED THE RESPONSIBILITY TO KEEP US INFORMED OF ANYTHING THAT MAY IMPACT THE PROGRESS.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00214
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/01/2005 INSP - FOLLOW UP CODE ENFORCE JORTA Approved I WENT TO THE MOTEL FOR A FOLLOW UP INSPECTION AND FOUND THE OWNER THERE CLOSING THE GATES. ALL UNITS HAVE BEEN VACATED AND SECURED. THE POWER HAS BEEN SHUT OFF BY TEP AND ALSO THE GAS METER IS PINNED OFF. I WILL BE REQUESTING THAT THE GAS AND ELECTRIC BE KEPT OFF UNTIL A CLEARANCE IS GRANTED BY THE CITY OF TUCSON. THERE WAS A MR BT PATTEL LOOKING AT THE UNITS. A PROSPECTIVE BUYER. MR ROBERT STEWART INDICATED THAT HE WANTS TO GET A PLAN AND PERMITS TO REHAB ALL UNITS. I TOLD HIM BEST TO GET AN ARCHITECT AND TO TALK WITH DEVELOPMENT SERVICES FOR ANY APPEALS TO THE STRUCTURE OR CHARGES TO.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00214
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
04/14/2005 CONTACTED BY PHONE
05/28/2004 NOTICE OF VIOLATION ISSUED
05/28/2004 COURT ORDERED ABATEMENT
03/15/2004
06/11/2005 CONTACTED BY MAILING
11/10/2005 2ND ASSOC CASE NUMBER: A new case number relating to the citation (same violations) will be found in case number: T04DV00910.
02/07/2006 OFFICE VISIT

Documents

File Name Document Type  
FORGOT TO WIRE-NUT AND BLANK-OFF BOX.JPG None VIEW
IN BETWEEN ROOF STRUCTURES II.JPG None VIEW
IN BETWEEN ROOF STRUCTURES WIRES NOW INSULATED.JPG None VIEW
MAIN SIGN.JPG None VIEW
N. PORTION OVERHEAD RESUPPORT.JPG None VIEW
RESUPPORT II.JPG None VIEW
RESUPPORT III.JPG None VIEW
NOTICE AND ORDER BY JIM HURD ().PDF None VIEW
NOTES .PDF None VIEW