Case: T04DV00214

Parcel: 115150290


Addresses:

2115 N ORACLE RD


Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00214

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/25/2004 INSP - INITIAL CODE ENFORCMENT Correction Required 3/18/04, VISITED PROPERTY, TOOK PICTURES, WALKED COMPLETE EXTERIOR OF PROPERTY, FOUND ISSUES IN NEED OF REPAIR, FRONT PART OF STRUCTURE, OFFICE, STRUCTURE BRICKS SEPERATING AND HAS MOVED, HAS EXPOSED ELECTRICALAT CONVENIENCE OUTLET, 2ND DOOR DETERIORATED COMMING APART, UNIT SHOWS BED, CLOTHES, LOOKS OCCUPIED IN UNIT, CONVENIENCE OUTLET ON EXTERIOR NOT WEATHER PROTECTED, PAINT ON EXTERIOR PEELING AND CHIPPING AWAY, GROUNDSMAN MIKE HICKEY WAS HIRED TO DO CLEAN UP OF GROUNDS ON PROPERTY, ALSO LIVES IN ONE OF THE UNITS, LAUNDRY AREA HAS BEEN INSTALLED WHERE 2 CARPORTS WERE DESIGNATED, ROOF HAS BEEN INSTALLED OUT OF 2"X4" AND SPANDS APPOX. 10', ELECTRICAL CIRCUITS HAS BEEN ADDED FOR WASHERS AND DRYERS, OPEN AND EXPOSED WIRING, ELECTRICAL SERVICE HAS BEEN DOUBLED LUGGED TO SUPPY THIS ELECTRICAL SERVICE TO EQUIPMENT, NONE OF WHICH IS GFCI PROTECTED, 1 LINE TO WASHER, ONE TO DRYER, ANOTHER TO JUNCTION BOX UP AT TOP, HAS HAD LIGHTS INSTALLED ALSO, SHOP LIGHTS, (FLOURESENT) THIS TYPE OF INSTALLATION WOULD NOT PASS INSPECTION, THEREFORE I DO NOT BELIVE ANY PERMITS HAS BEEN SECURED FOR ROOF OR ELECTRICAL CIRCUIT ADDITIONS.
UNIT 1
HAS BROKEN WINDOW IN REAR OF STRUCTURE.
UNIT 2
HAS EXPOSED ELECTRICAL WIRING IN REAR OF STRUCTURE, COOLER LEAKING ON TO GROUND ALLOWING WATER TO STAND AND PUDDLE.
UNIT 3
ADDED CONVENIENCE OUTLET, NOT WEATHER PROTECTED NOR GFCI PROTECTED.
UNIT 4
ELECTRICAL SERVICE IN CARPORT MISSING COVER, ALSO SHOWING DOUBLE LUGGING IN PANEL BOX, ELOECTRIC BOX IN REAR OF STRUCTURE HAS EXPOSED WIRING, ADDED CONVENIENCE OUTLET IN STALLED NOT WEATHER PROTECTED OR GFCI PROTECTED, HOT WATER TANK MISSING PRESSURE RELIEF VALVE DRAIN LINE.
UNIT 5
MORTOR MISSING IN BETWEEN BRICKS, PAINT PEELING AND CHIPPING AWAY,
UNIT 6
ELECTRIC SERVICE PANEL IN CARPORT SHOWING DOUBLE LUGGING ON 2 BREAKERS, ADDED ELECTRICAL CIRCUITS, WEATHER PROTECTED BOX MISSING COVERS,
UNIT 7
ADDED ELECTRICAL CIRCUIT CONVENIENCE OUTLET, LIGHT BULB BROKEN WITH FILAMENT HANGING LOOSE, EXPOSED WIRING, FRONT DOOR JAMB HAS BEEN REPLACED BUT NOT FINISHED, RAW WOOD EXPOSED, NO SEALANT, MORTOR MISSING FROM IN BETWEEN BRICKS, REAR WINDOW BROKEN.
UNIT 8
BROKEN LIGHT BULB IN FIXTURE, MORTOR MISSING FROM IN BETWEEN BRICKS, PAINT PEELING AND CHIPPING AWAY, COOLER LEAKING ON TO GROUND AND ALLOWING WATER TO STAND AND PUDDLE, TELEPHONE BOX LAYING ON GROUND, NOT SECURED TO STRUCTURE, ELECTRIC BOX MISSING DEAD PLATE, HAS WROUGHT IRON SECURITY BARS INSTALLED NOT OF BREAK AWAY TYPE IN CASE OF FIRE OR PANIC.
UNIT 9
ELECTRIC CIRCUIT ADDED, HOT WATER TANK PRESSURE RELIEF VALVE DRAIN LINE NOT INSTALLED, BATH WINDOW BROKEN,
UNIT 10
ADDED ELECTRICAL CIRCUIT, GFCI CONVENIENCE OPUTLET, 2 WINDOWS BROKEN, STRUCTURE SHOWS CRACKS,
UNIT 11
EXPOSED ELECTRICAL WIRING, KNOCK OUT PLUG MISSING AT BOX, CONVENIENCE OUTLET BURNT NOT WEATHER PROTECTED,
UNIT 12
NEW HOT WATER TANK HAS BEEN INSTALLED, RESEARCH FOR PERMIT.
UNIT 14
NEW HOT WATER TANK INSTALLED, RESEARCH FOR PERMIT.
UNIT 15
ELECTRIC SERVICE PANEL SHOWS DOUBLE LUGGING ON 2 SEPERATE BREAKERS,
UNIT 16
HAS BROKEN WINDOW
UNIT 17
ADDED ELECTRICAL CIRCUITS WHICH GO DIRECTLY INTO INTERIOR OF UNIT, PAINT ON WALLS AND FACIA MISSING,
ALL OF PROPERTY HAS PAINT PEELING AND CHIPPING AWAY, IN NEED OF PROTECTIVE COATING.
POOL AREA
POOL AREA HAS FENCING AROUND POOL, GATE IN NEED OF REPAIR, SUPPORT POST AT GATE IN NEED OF REPAIR, SOME AREA HAS OPENING LARGER THAN 4", POOL HOLDING SOME RAIN WATER, APPOX 2-3 FEET, HAS TURNED DARK.