Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

01/06/2004

Applicant:

G & I ARCADIA LLC

Description:

COMPLAINT:MIN HOUSING-NO HOT WATER/UNIT 516 CALLED ON 03/9/04

Outstanding Inspections

Case Number: T04DV00011
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
01/07/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Correction Required VISITED SITE, MET WITH MANAGER, COMPLEX MAINTENANCE SUPERVISOR AND CONTRACTOR. ALL INFORMED ME THAT TEMPORARY BYPASS OF HOTWATER LOOP WAS NECESSARY DUE TO HARD FREEZE HAS BROKEN LOOSE SECTION OF ALKALINE BUILD UP IN EXISTING PIPES. CONTRACTOR RICK PELLER FROM KODIAK MECH. SYSTEM WALKED INSP. THROUGH SITE. ALTERATION TO 3" LINE HAVE BEEN BY PASSED AND OPENING IN GROUND HAVE BEEN CORDED OFF. ASK IF WORK WAS UNDER PERMIT AND INSPECTION DONE BY DSD PLUMBING INSPECTOR. MANAGER AND CONTRACTOR WILL INFORM OWNER AND CONTRACT WILL START PROCESS. ALKALINE IN SYSTEM HAS BLOCKED OFF WATER SUPPLY TO SOME UNITS. AFFECTED WERE SHOWER HEADS, AREATORS FOR KITCHEN AND BATHROOM SINKS AND TOILETS. NANAGEMENT AND SUPERVISOR STATED THAT TECH HAVE ALREADY ADDRESSED THE CLOGGING PROBLEMS WITH WATER SYSTEMS IN UNITS. INFORMED MANAGER INSP WILL BE CONTACTING ALL UNITS LISTED ON COMPLAINT FORM TO VERIFY HOT WATER HAS BEEN RESTORED. WALK THROUGH INSP OF UNIT 104, 106, 203, 206, 211, 212, 419, 511, 609, 712, 714, 716, 803, 811, 814 WERE DONE AND ALL DID HAVE HOTWATER, PRESSURE WAS SOME WHAT LOW. UNIT 509, 515, 618 & 709 WERE NOT AT HOME AND CARD WITH CONTACT NUMBER WAS LEFT ALL UNITS ENTERED WERE CHECKED FOR MIN HOUSING ISSUES NONE WERE FOUND, ALL SMOKE DETECTORS WERE CHECKED AND FOUND WORKING. ALL UNITS CONTACTED DID STATE THAT COMPLEX MANAGER HAD MADE ARRANGEMENTS FOR TENANT HAVING PROBLEMS WITH HOTWATER TO TAKE SHOWERS AND OR BATHS AT OTHER UNITS WERE NO PROBLEMS EXISTED. ASKED TENANT IF MANAGEMENT WERE POSTING UNITS WHEN HOT WATER WAS EXPECTED TO BE SHUT DOWN AND IF DURATION TIME WAS LISTED, SOME REPLIED YES AND OTHERS REPLIED NO. EXPLAINED TO ALL, CONTRACTOR IS MAKING ATTEMPTS TO CORRECT PROBLEMS AND MANAGEMENT ALSO. DID WALK THROUGH SITE. DID FIND SEVERAL MINOR ELECTRICAL VIOLATION AND FOUND SOME POOL VIOLATIONS AS WELL. SEVERAL POOL FENCING SECTIONS WERE FOUND TO HAVE OPENING LARGER THAN 4" SEVERAL WROUGHT IRON TUBING HAVE BEEN DAMAGED AND BENT. LIST OF ELECTRICAL VIOLATION ARE ATTACHED TO THIS REPORT. WILL ISSUE NOV FOR POOL AND ELECTRICAL VIOLATION. PICTURES WERE TAKEN. 1. SOUTH OF UNIT 815 EXPOSED ELECTRICAL BOX MISSING COVER PLATE. 2. WATER LEAKING FROM POSSIBLE SWIMMING POOL PUMP ROOM S-815. 3. WEATHER PROOF ON CLOSURE LACKING FOR WATER FOUNTAIN AT S.W. SIDE OF LAUNDRY ROOM. 4. BUILDING #5 EXPOSED ELECTRICAL, ELECTRICAL CONDUCTOR E.M.T. NOT SECURED PROPERLY S.E CORNER. 5. COVER MISSING FROM FITTING, EXPOSE ELECTRICAL COMING UP FROM UNDER GROUND AT BUILDING #6 SW. CORNER. 6. ELECTRICAL JUNCTION BOX MISSING COVERPLATE ALLOWING EXPOSED ELECTRICAL CONDUCTORS BUILDING #5 N.E. CORNER ALSO ELECTRICAL DISONNECT HAS BEEN PULLED AWAY FROM WALL FOR A.C. UNITS AT N.W. CORNER.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00011
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/15/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VIOLATIONS ABATED VISITED SITE ON FOLLOW UP INSP. MADE CONTACT WITH MAINTAINANCE SUPERVISOR, INSPECTED REPAIRS TO POOL PUMP PLUMBING. LEAKING ELBOW FITTING HAS BEEN REPAIRED. PREVIOUS INSPECTION ON 3/9/04 FOUND ALL OTHER VIOLATION ABATED. CONVERSATION WITH MAINTAINANCE SUPERVISOR & MANAGER INFORMED ME TWO ADDTIONAL HOT WATER HOLDING TANKS ARE SCHEDULED TO BE INSTALLED STARTING THE 19TH OF MARCH OF 04. THIS INSTALLATION WILL SLOVE PROBLEM OF TIME LAG OF HOT WATER USE DURING PEAK HOUR USAGE. PICTURE WAS TAKEN. MANAGEMENT HAS COMPLIED, CLOSE CASE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00011
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
02/09/2004 CONTACTED BY PHONE
02/10/2004 NOTICE OF VIOLATION ISSUED
02/10/2004 COURT ORDERED ABATEMENT

Documents

File Name Document Type  
MVC-001S.JPG IMAGES VIEW
MVC-043S.JPG IMAGES VIEW
MVC-044S.JPG IMAGES VIEW
MVC-045S.JPG IMAGES VIEW
MVC-046S.JPG IMAGES VIEW
MVC-047S.JPG IMAGES VIEW
MVC-048S.JPG IMAGES VIEW
MVC-049S.JPG IMAGES VIEW
MVC-021S.JPG IMAGES VIEW
MVC-022S.JPG IMAGES VIEW
MVC-023S.JPG IMAGES VIEW
MVC-024S.JPG IMAGES VIEW
MVC-025S.JPG IMAGES VIEW
MVC-026S.JPG IMAGES VIEW
MVC-027S.JPG IMAGES VIEW
MVC-028S.JPG IMAGES VIEW
MVC-029S.JPG IMAGES VIEW
MVC-030S.JPG IMAGES VIEW
MVC-031S.JPG IMAGES VIEW
MVC-032S.JPG IMAGES VIEW
MVC-033S.JPG IMAGES VIEW
MVC-034S.JPG IMAGES VIEW
MVC-035S.JPG IMAGES VIEW
MVC-036S.JPG IMAGES VIEW
MVC-037S.JPG IMAGES VIEW
MVC-038S.JPG IMAGES VIEW
MVC-039S.JPG IMAGES VIEW
MVC-040S.JPG IMAGES VIEW
MVC-041S.JPG IMAGES VIEW
MVC-042S.JPG IMAGES VIEW
250 N ARCADIA AV. BULD. 1-8.PDF DOCUMENTS VIEW