Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/26/2003

Applicant:

GRIJALVA ALBERTO A & GRACIELA G JT/RS

Description:

COMPLAINT:MIN HOUSING-COOLER NOT WORKING CORRECTLY.

Outstanding Inspections

Case Number: T03DV00804
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
09/12/2003 INSP - INITIAL CODE ENFORCMENT HLOPEZ Violation VIOLATIONS FOUND VISITED SITE , MET WITH TENANT & WALKED PROPERTY. VIOLATIONS FOUND ARE AS FOLLOWS (1) RECEPTACLES WERE TESTED THOUGH OUT STRUCTURE, REVERSED POLAIRITY IN KITCHEN OUTLETS, OPEN GROUNDS IN WEST,SOUTHWEST & SOUTH EAST BEDROOMS. RECEPTACLE COVER PLATES LACKING IN SOUTH EAST BEDROOM, FOR WASHING MACHINE & DYER RECEPTACLES. ELECTRICAL SERVICE HAS BEEN UP-GRADED, 2 PRONG RECEPTACLE WAS FOUND IN LAUNDRY ROOM. ADDITION OF 3 CIRCUTS, 1- FOR 220 OUTLET IN LAUNDRY ROOM. 1- FOR EXTERIOR LIGHTPOST IN BACK YARD WITH ELECTRICAL CONDUCTOR (ROMEX) NOT IN CONDUIT AND 1- 40 AMP BREAKER BOX WITH ELECTRICAL CONDUCTORS IN CONDUIT CONNECTED. THESE ITEMS ARE EVIDENCE OF W/O/P WILL DO RESEARCH & CHECKED FOR PERMITS. (2) LACKING REQUIRED SMOKE DETECTOR. (3) SOUTH EAST BEDROOM WINDOW CRANK NOT OPERATIONAL. (4) DRYER LACKING EXHAUST VENT PIPE. (5) NEW 30 GALLON HOTWATER HEATER HAS BEEN INSTALLED & IS LACKING DRAINPIPE FOR T.P.R. VALVE AND FLUE VENT JOINTS HAVE NOT BEEN SEALED. ALTERATION & ADDITION TO GAS PIPING FOR DRYER HAVE BEEN MADE. WILL DO RESEARCH & CHECK FOR PERMIT. PICTURES WERE TAKEN. WILL ISSUE N.O.V. WHEN RESEARCH IS COMPLETE.
12/31/2003 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Violation VISITED SITE MET FOR SCHEDULED MEETING WITH OWNER AND CONTRACTOR (ELECTRICAL). WENT OVER VIOLATIONS, OWNER HAS REMOVED GAS PIPING IN VIOLATION FOR GAS DRYER. OWENR IN PROCESS OF APPLYING FOR COMBE PERMIT FOR PLUMBING AND ELECTRICAL ISSUES. ELECTRICAL CONTRACTOR WILL INSTALL G.F.I.C. CIRCUITS IN KITCHEN AND BATHROOM REMOVE ALL NON GROUNDED RECEPTACLES THROUGHOUT STUCTURES REMOVE (2) ILLEGAL CIRCUITS IN CARPORT AREA AND INSTALL NEW. PERMITTED CIRCUIT FOR EXTERIOR LIGHTING. PLUMBING CONTRACT WILL REMOVE NON-APPROVED GAS VALVES FOR HOT WATER HEATER AND INSTALL AGA APPROVE VALVES EASL FLUE PIPE CONNECTION AND INSTALL COPPER DRAIN LINE FOR TPR VALVE. ALSO WILL BE COVERED UNDER COMBO PERMIT FOLLOW UP INSPECTION IS SCHEDULED FOR JAN 18TH. ALL VIOLATION TO BE ABATED BY THEN. MAGNET ELECTRIC, RENE SALAZAR INFO UNDER PEOPLE.

Completed Inspections

Case Status: COMPLIAN
Case Number: T03DV00804
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/26/2004 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Approved VIOLATIONS ABATED. VISITED SITE, MET WITH OWNER. CHECKED REMAINING UNGROUNDED RECEPTACLES. OWNER HAD ELECTRICAL CONTRACTOR REMOVE 3 PRONG RECEPTACLES & INSTALLED 2 PRONG RECEPTACLES. REPAIRS WERE DONE UNDER COMBO PERMIT TO3CM05902. OWNER HAS COMPLIED CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00804
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/22/2004 CONTACTED BY PHONE
08/26/2003 CONTACTED IN PERSON
12/22/2003 NOTICE OF VIOLATION ISSUED
12/22/2003 COURT ORDERED ABATEMENT