Case: T02VL02179
Case Details
Entered Date:
10/24/2002
Applicant:
BREWSTER FRANK L & HELEN V TR
Description:
COMPLAINT:SABER
Outstanding Inspections
Case Number: T02VL02179
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/30/2002 | INITIAL CODE VIOLATION | RSALDATE | Correction Required | SABER INITIAL INSPECTION: THIS CASE HAS BEEN CONVERTED TO A SABER CASE AND WAS INSPECTED BY RICK SALDATE, RAY CAMACHO & GLENN D'AURA. PROPERTY: LARGE PARCEL CONSISTING OF 2-BED HOUSE ALONG HEDRICK, MOBILE HOME ON SOUTH-WEST CORNER OF PROPERTY AND SMALL MOTOR HOME OCCUPYING THE SOUTH-EAST CORNER. UNIT-810: HAZARDOUS ELECTRICAL: 1) THE MAIN SERVICE WAS FOUND IN A HAZARDOUS CONDITION AND LACKING PERMITS. THE MAIN SERVICE IS LOCATED ON ANOTHER STRUCTURE (WHICH HE PREVIOUSLY OWNED) NEXT DOOR AND RUNS UNDERGROUND TO UNIT 810. THE OWNER IS UTILIZING THE ORIGINAL SERVICE (MOUNTED ON 810) AS A J-BOX AND STILL HAS ALL OF THE INTERIOR COMPONENTS IN TACT. A 220-AMP CIRCUIT AND RECPETICLE FOR A DRYER AND TWO DISCONNECT BOXES HAVE BEEN ADDED LACKING PERMITS TO THE OLD MAIN SERVICE. 2) THE RECEPTICAL IN THE REAR PORCH IS NOT AN EXTERIOR TYPE. 3) THE INTERIOR BREAKER PANEL IS IN DISREPAIR IN THAT THE DEADFRONT DOES NOT CLOSE POSSIBLY DUE TO INCORRECT BREAKERS. 4) THE COOLER WAS INSTALLED IN A HAZARDOUS MANNER IN THAT THE SWITCH HAS BEEN WIRED UTILIZING LAMP CORD AND IS PLUGGED INTO A RECEPTICAL WHICH WAS INSTALLED W/O PERMITS. UNKNOWN IF CIRCUIT IS DEDICATED. 5) ELECTRICAL FIXTURES WERE FOUND INCORRECTLY INSTALLED AND IN A HAZARDOUS CONDITION. THE LIGHT FIXTURE IN THE PANTRY WAS COVERED WHEN THE UNIT WAS STUCCOD. THE FAN IN THE LIVING ROOM IS POWERED BY THE ADDITION OF A CIRCUIT LACKING PERMITS AND THE FAN CONNECTIONS MAY NOTBE MADE IN THE J-BOX. THE J-BOX DOES APPEAR TO CONNECT THE CONTINUATION OF THE CIRCUIT. A LIGHT FIXTURE IN THE NW BEDROOM WAS ALSO FOUND WIRED WITH AN ADDED CIRCUIT (POSSIBLY THE CONTUATION OF FAN CIRCUIT) AND CONNECTIONS INCORRECTLY MADE. . |
| 11/13/2002 | FOLLOW UP CODE VIOLATION | RCAMACHO | Correction Required | RESEARCH INFO: NO RECORD OF ANY ELEC. PERMIT AT 810 E HEDRICK. ALL ELEC. PERMITS UNDER 814 WHICH IS NO LONGER OWNED BY FRANK BREWSTER. A 14-DAY NOTICE REGARDING ILLEGAL DWELLING UNIT HAS BEEN ISSUED BY ZONING HEATHER THRAHLL.SPOKE WITH JULIE WITH TEP. MUST HAVE METER NUMBERS FOR HISTORY ON THIS ADDRESS. NOTHING ON THIS ADDRESS IN THERE SYSTEM. CAMBER IN METAL TRUSSES IS ORIGINAL CAMBER SET FOR WATER DIVERSION. TRUSSES ARE NOT FAILING AT THIS TIME. A COMBO PERMIT IS NECESSARY FOR ALL REPAIRS DONE W/O PERMITS OR INSP. TO INCLUDE: INSTALLATION OF WALL HEATER, GAS LINES TO METER. ELEC METER UNDERGROUND CONNECTION TO 220 DRYER. NEW WATER HEATER INSTALLATION.ALL INTERIOR REPAIRS NECESSARY TO COMPLY. DRAWINGS OF ALL WORK DONE FOR DSD RECORDS. AFTER FURTHER RESEARCH AT DSD FOUND THE ORIGINAL PERMIT # 08122112 WAS ISSUED ON 2/8/95. ON 2/9/95 ELEC METER/ WALL FURNACE WAS ADDED TO THE SAME PERMIT. ON 2/19/95 A GAS LINE METER TO RSE WAS ALSO ADDED. ALL ISSUES ON THE SAME PERMIT WAS ALLOWED IN 1995. ON 2/13/95 FRANK BREWSTER REQUESTED A REFUND ON ELECTRICAL PERMIT FEES. HE HAD DECIDED TO WAIT ON ELEC METER WORK. REQUEST WAS APPROVED BY PAUL SWIFT ON 4/24/95. THEREFORE NONE OF THESE ISSUES WERE EVER INSPECTED OR FINALED. NEW PERMITS MUST BE PULLED TO COVER ALL WORK DONE THAT MUST BE INSPECTED. WILL INSP ROOF LINE AT 11/18/02 INSP OF 3027 N TYNDALL AVE. FOR SEPERATION OR FAILURE OF WEST WALL. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T02VL02179
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 12/31/2002 | NOTICE AND ORDER ISSUED |