Case: T02VL02179

Parcel: 11308291A


Addresses:

810 E HEDRICK DR

Inspection Status: Correction Required

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
04/15/2003 FOLLOW UP CODE VIOLATION Correction Required CONDUCTED FOLLOW UP INSPECTION WITH GLENN (TFD) ALL REPAIRS COMPLETED. ALL VIOLATIONS ABATED. EGRESS BEDROOM WINDOWS MEET CODE DUE TO OWNER INSTALLING FABRICATED HINGES TO ALLOW PROPER EGRESS DIMENSIONS. INFORMED OWNER NOT TO MODIFY REPAIRS DONE BACK TO ORIGINAL STATE. GLENN AND RICK S.ALSO AGREE WITH DECISION. DECISION MADE BETWEEN RICK S. GLENN AND INSPECTOR TO CLOSE CASE UNDER COMPLIANCE.
04/10/2003 FOLLOW UP CODE VIOLATION Correction Required FOLLOW UP INSPECTION:

CONDUCTED BY RICK S. & RAY C., OTHERS PRESENT WERE MR. BREWSTER AND THE GENTLEMEN WHO IS IN PROCESS OF PURCHASING PROPERTY. NOTE: NUMBERS FOLLOWING ARE ASSOCIATED WITH THE NUMBERS ON THE NOTICE & ORDER DATED 12/27/02.

1) COMPLIANCE: OWNER HAS SECURED PERMITS AND FINALED. RAY RELAYED THAT HE HAS SEEN PERMITS IN COMPUTER BUT SAID WILL CHECK IN ORDER TO MAKE SURE. THE 220-AMP CIRCUIT HAS BEEN REMOVED.

2) COMPLIANCE. THE OWNER HAS KEPT THE SAME PREVIOUS WINDOWS WHICH WERE NOT IN COMPLIANCE AND MODIFIED THEM. HE HAS ADDED CABNIT HINGES TO THE EDGES SO THE WHOLE WINDOW AND FRAME SWING OPEN LIKE A DOOR. IN ORDER TO LOCK HE HAS ADDED HOOK AND EYE TYPE LOCKS ON THE INSIDE. THE OWNER AND MR. BREWSTER WERE INFOMED THAT THIS METHOD DOES PASS THE REQUIREMENTS BUT THAT IF THEY SREW DOWN THE WINDOW IN THE FUTURE THAT IT WILL BE IN VIOLATION. RAY CAMACHO WILL BE CALLING TEP TO HAVE THEM MOVE ACHORING WIRES TO POLE ALONG THE WEST SIDE OF HOUSE. WIRES HINDER ADEQUATE OPENING OF WINDW TO BEDROOM. IF TEP WILL NOT THEN OWNERS WILL HAVE TO ADDRESS ISSUE.

3) COMPLIANCE.

4) COMPLAINCE: OWNER STILL NEEDS TO COVER ONE VENT IN BEDROOM.

5) COMPLIANCE. HAS ELECTRICIAN WHO BECAME SICK THAT NEEDS TO PUT WIRING IN FAN IN CONDUIT.

6) COMPLIANCE: REMOVED.

7) COMPLAINCE: REMOVED.

NOTE: RAY WILL CONDUCT ONE FINAL RE INSPECTION FOR ELECTRICAL OF VIOLATION #5, WINDOW FOR VIOLATION # 2. AND VERIFY PERMITS IN COMPUTER.
04/04/2003 FOLLOW UP CODE VIOLATION Correction Required CONTACTED GEORGE (MANAGER) PER RICK S. TO CONTACT OWNER TO SET-UP FOLLOW UP INSPECTION ON PROPERTY. GEORGE STATED ALL REPAIRS TO COOLERS AND WIRING ON ROOF HAS BEEN COPMPLETED BY ELECTRICAL CONTRACTOR. CONTRACTOR TO CONTACT DNR WITH STATUS.
11/13/2002 FOLLOW UP CODE VIOLATION Correction Required RESEARCH INFO:
NO RECORD OF ANY ELEC. PERMIT AT 810 E HEDRICK. ALL ELEC. PERMITS UNDER 814 WHICH IS NO LONGER OWNED BY FRANK BREWSTER.
A 14-DAY NOTICE REGARDING ILLEGAL DWELLING UNIT HAS BEEN ISSUED BY ZONING HEATHER THRAHLL.SPOKE WITH JULIE WITH TEP. MUST HAVE METER NUMBERS FOR HISTORY ON THIS ADDRESS. NOTHING ON THIS ADDRESS IN THERE SYSTEM.

CAMBER IN METAL TRUSSES IS ORIGINAL CAMBER SET FOR WATER DIVERSION. TRUSSES ARE NOT FAILING AT THIS TIME.

A COMBO PERMIT IS NECESSARY FOR ALL REPAIRS DONE W/O PERMITS OR INSP.
TO INCLUDE: INSTALLATION OF WALL HEATER, GAS LINES TO METER. ELEC METER UNDERGROUND CONNECTION TO 220 DRYER. NEW WATER HEATER INSTALLATION.ALL INTERIOR REPAIRS NECESSARY TO COMPLY. DRAWINGS OF ALL WORK DONE FOR DSD RECORDS.

AFTER FURTHER RESEARCH AT DSD FOUND THE ORIGINAL PERMIT # 08122112 WAS ISSUED ON 2/8/95.
ON 2/9/95 ELEC METER/ WALL FURNACE WAS ADDED TO THE SAME PERMIT.
ON 2/19/95 A GAS LINE METER TO RSE WAS ALSO ADDED. ALL ISSUES ON THE SAME PERMIT WAS ALLOWED IN 1995.
ON 2/13/95 FRANK BREWSTER REQUESTED A REFUND ON ELECTRICAL PERMIT FEES. HE HAD DECIDED TO WAIT ON ELEC METER WORK. REQUEST WAS APPROVED BY PAUL SWIFT ON 4/24/95. THEREFORE NONE OF THESE ISSUES WERE EVER INSPECTED OR FINALED. NEW PERMITS MUST BE PULLED TO COVER ALL WORK DONE THAT MUST BE INSPECTED.

WILL INSP ROOF LINE AT 11/18/02 INSP OF 3027 N TYNDALL AVE. FOR SEPERATION OR FAILURE OF WEST WALL.
10/09/2002 FOLLOW UP CODE VIOLATION Correction Required AFTER MEETING WITH RICK S. IN OFFICE. POSTED TRAVEL TRAILER WITH 30-DAY NOTICE ADB DWELLING IS MANIFESTLY UNSAFE FOR THE PURPOSE FOR WHICH IT IS BEING USED DUE TO THE IMPROPER ELECTRICAL CONNECTION WHICH WAS NEVER PERMITTED. ALSO DWELLINGIS NOT SELF CONTATINED IN WHICH IT DOES NOT INCLUDE REQUIRED BATH FACILITIES. 30-DAYS TO SECURE ALL REQUIRED PERMITS AND ZONING ISSUES. ALSO REFERR TO 3027 N. TYNDALL AV.