Case: T02VL02179

Parcel: 11308291A


Addresses:

810 E HEDRICK DR

Inspection Status: Correction Required

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
10/30/2002 INITIAL CODE VIOLATION Correction Required SABER INITIAL INSPECTION:
THIS CASE HAS BEEN CONVERTED TO A SABER CASE AND WAS INSPECTED BY RICK SALDATE, RAY CAMACHO & GLENN D'AURA.

PROPERTY: LARGE PARCEL CONSISTING OF 2-BED HOUSE ALONG HEDRICK, MOBILE HOME ON SOUTH-WEST CORNER OF PROPERTY AND SMALL MOTOR HOME OCCUPYING THE SOUTH-EAST CORNER.

UNIT-810:

HAZARDOUS ELECTRICAL: 1) THE MAIN SERVICE WAS FOUND IN A HAZARDOUS CONDITION AND LACKING PERMITS. THE MAIN SERVICE IS LOCATED ON ANOTHER STRUCTURE (WHICH HE PREVIOUSLY OWNED) NEXT DOOR AND RUNS UNDERGROUND TO UNIT 810. THE OWNER IS UTILIZING THE ORIGINAL SERVICE (MOUNTED ON 810) AS A J-BOX AND STILL HAS ALL OF THE INTERIOR COMPONENTS IN TACT. A 220-AMP CIRCUIT AND RECPETICLE FOR A DRYER AND TWO DISCONNECT BOXES HAVE BEEN ADDED LACKING PERMITS TO THE OLD MAIN SERVICE. 2) THE RECEPTICAL IN THE REAR PORCH IS NOT AN EXTERIOR TYPE. 3) THE INTERIOR BREAKER PANEL IS IN DISREPAIR IN THAT THE DEADFRONT DOES NOT CLOSE POSSIBLY DUE TO INCORRECT BREAKERS. 4) THE COOLER WAS INSTALLED IN A HAZARDOUS MANNER IN THAT THE SWITCH HAS BEEN WIRED UTILIZING LAMP CORD AND IS PLUGGED INTO A RECEPTICAL WHICH WAS INSTALLED W/O PERMITS. UNKNOWN IF CIRCUIT IS DEDICATED. 5) ELECTRICAL FIXTURES WERE FOUND INCORRECTLY INSTALLED AND IN A HAZARDOUS CONDITION. THE LIGHT FIXTURE IN THE PANTRY WAS COVERED WHEN THE UNIT WAS STUCCOD. THE FAN IN THE LIVING ROOM IS POWERED BY THE ADDITION OF A CIRCUIT LACKING PERMITS AND THE FAN CONNECTIONS MAY NOTBE MADE IN THE J-BOX. THE J-BOX DOES APPEAR TO CONNECT THE CONTINUATION OF THE CIRCUIT. A LIGHT FIXTURE IN THE NW BEDROOM WAS ALSO FOUND WIRED WITH AN ADDED CIRCUIT (POSSIBLY THE CONTUATION OF FAN CIRCUIT) AND CONNECTIONS INCORRECTLY MADE. .
10/24/2002 INITIAL CODE VIOLATION Correction Required CLOSURE: INITIAL PROBLEMS WITH LOCATING OWNER. E-MAIL CONTACT WITH MIKE RANKIN AND PEGGY TATE. CONFORMATION THAT FRANK BREWSTER OWNS THIS PROPERTY. TENANT AND MANAGER OF HALF WAY HOUSE @ 3027 N. TYNDALL BOTH STATED FRANK BREWSTER WAS ONWER. SEVERAL ATTEMPTS TO CONTACT FRANK BREWSTER BY LEAVING MESSAGES ON HIS VOICE MAIL HAVE RESULTED IN NO CALLS FROM OWNER.
10/02/2002 INITIAL CODE VIOLATION Correction Required MET WITH ROB H. ON SITE WITH TPD. FOUND NO ELECTRICAL UTILITIES TO PROPERTY SMALL GENERATOR AND SOLAR ONLY. POSTED NOTICE ADB DUE TO LACK OF REQUIRED ELECTRICAL UTILITIES TO PROPERTY.TENANT WILL ATTEMPT TO RENEW OLD EXPIRED PERMIT # T99EL00327 WHICH HAS EXPIRED AND WAS NEVER ISSUED.STRUCTURE MUST REMAIN SECURED FROM UNAUTHORIZED ENTRY AND REMAIN VACANT UNTIL VIOLATIONS HAVE BEEN ABATED.MARTIN ROMERO CALLED ON SITE FOR DEBRIS FOUND ON SITE. ALSO SERVED 30-DAY NOTICE FOR DEBRIS. SEE PICTURES. GLENN TFD WAS NOT ABLE TO ENTER AT THIS TIME DUE TO TENANT REFUSING ENTRY. RECEIVED E-MAIL FROM HEATHER THRAHLL. MOBILE HOME ON SITE IS NOT LEGAL DUE TO PROPERTY NOT BEING ZONED COMMERCIAL. ALSO HAVE ARIALS SHOWING THE EXISTANCE OF GARAGE STRUCTURE BACK IN 1967.