Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

08/02/2001

Applicant:

RASEY RYAN TR

Description:

Min-house SABER

Outstanding Inspections

Case Number: T01VL02233
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/06/2001 FOLLOW UP CODE VIOLATION RSALDATE Correction Required FOLLOW UP INSPECTION: NOTE: NUMBERS CORRESPOND TO ORIGINAL N & O. A) UNIT-A: (1) ADDITION ON EAST SIDE HAS NOT BEEN ADDRESSED. CIELING IN LIVING ROOM HAS BEEN REPLACED WITH ELECTRICAL REMOVED IE; RECESSED LIGHTING AND FAN. ELECTRICAL IN BEDROOM HAS BEEN REMOVED. ELECTRICAL SUPPLYFROM MAIN SERVICE HAS NOT BEEN PERMITTED, BUT OWNER IS WORKING ON. WALL HEATER HAS NO PERMITS ACCORDING TO COMPUTER BUT NOW WORKS. (2) CIELINGS, INTERIOR AND EXTERIOR HOLES HAVE BEEN SEALED. TENANT RELAYED THAT STRUCTURE DID NOT LEAK ON RECENT RAINS. FRONT DOOR WEATHER PROTECTION VIOLATION REMOVED PER APPEAL BY OWNER. BROKEN WINDOW REPAIRED. ADDITION HAS NOT BEEN ADDRESSED. (3) HEATER IS WORKING BUT NO PERMIT PULLED. (4) GENERAL DILAPIDATION ISSUES REPAIRED. KITCHEN SINK WAS MISSING DURING INSEPCTION BUT WAS DUE TO REPLACING. (5) EXPOSED WIRES IN CIELING REMOVED AS WELL AS CONDUIT. COVER PLATES REPLACED, NOT PERMITS NECESSARY DUE TO REMOVAL. (6) OFFICE ELECTRICAL ISSUES HAVE BEEN CORRECTED. (7) CONDUIT HAS BEEN RECONNECTED BUT STILL NOT PERMITTED. BLANK COVERS FOR LACKING BREAKERS IN SERVICE PANEL STILL MISSING. INTERIOR ELECTRICAL WORK HAS BEEN REMOVED. EXTERIOR OUTLETS ISSUE HAS BEEN ADDRESSED BY REMOVING ONE AND INSTALLING A WEATHER PRTECTED COVER ON THE OTHER. (8) CIELING REPAIRED AND ILLEGAL WIRING REMOVED. (9) APPEAL GRANTED. (10) BATHROOM WINDOW STILL DOES NOT FUNCTION FOR VENTILATION. (11) VIOLATION ABATED- DOORS HAVE BEEN CORRECTED FOR EXITING. (12) ABATED- SMOKE DETECTORS INSTALLED. ADDITIONAL VIOLATIONS: THE WALL HEATER, ALTHOUGH NOW OPERABLE, WAS INSTALLED W/O PERMITS. THE OWNER CLAIMS THAT IT IS ORIGINAL BUT THE INITIAL INSPECTION FOUND RECENT WORK AS IF BEING INSTALLED. THE TENANT ALS0 STATED THAT IT WAS A REPLACEMENT HEATER. THE OTHER UNITS HAVE THIER HEATERS LOCATED IN THE HALL WAYS. UNIT-A's HEATER LOCATION DOES NOT ALLOW FOR THE OTHER HABITAL ROOMS SUCH AS THE 2ND BEDROOM, KITHCHEN AND LIVING ROOM TO BE PROPERLY HEATED. THE FACIA ON THE ROOF WAS REPLACED AND THE EDGING WHICH KEEPS WATER OUT WAS NOT REPLACED. THE MAIN ELECTRICAL SERVICE DOES NOT HAVE THE CIRCUITS LABELED IN CASE OF SHUT OFF. THE KITCHEN LACKS A GFCI RECEPTICLE NEAR THE SINK AREAS. THIS IS NOW NECESSARY DUE TO THE LARGE AMOUNTS OF REMODEL AND ELECTRICAL WORK. B) UNIT-B: (13) VIOLATION ABATED IN THAT PLYWOOD HAS BEEN REPLACED AND A 4 X 4 POST HAS BEEN INSTALLED AS A SUPPORT. NOTE, WOOD HAS NOT BEEN PAINTED AND WILL RESULT IN THE DETERIORATION AT A FAST PACE RESULTING IN THE SAME SITUATION. (14) VIOLATION ABATED, OPENING CLOSED OFF. (15) VIOLATIONS NOT ABATED. GAS LINES STILL IN PLACE, HEAT NOT OPERATIVE, CLOSET ADDITION STILL IN PLACE, SUB PANEL STILL NOT PERMITED. (16) VIOLATION NOT ABATED, IN ADDITION TO SMALLER WINDOWS THE TENANT ALSO HAS AN A/C UNIT IN ONE OF THE WINDOWS. NOTE: ADDITONAL VIOLATIONS SUCH AS ROOF EDGING LACKING DUE TO CHANGE OF FACIA. SEWER VENT DETERIORATED AND NOW DOES NOT EXTEND PAST THE ROOF FOR PROPER SEWER OPERATION AND TO DISBURSE GAS IN SAFE MANNER. C) UNIT-C: (17) VIOLATION NOT IN COMPLIANCE. ELECTRICAL STILL NOT RESOLVED, CLOSET ADDTION STILL NOT PERMITTED. WALL HEATER STILL NOT PERMITTED. (18) VIOLATION APPEALED AND GRANTED. (19) SMOKE DETECTORS INSTALLED. (20) ALL VIOLATIONS RE GENERAL DILAPIDATION ABATED. (21) VIOLATION APPEALED AND GRANTED. (22) OWNER HAS PATCHED CRACK BUT CONTRACTOR WAS NOT OBTAINED TO ASSESS STRUCTURAL INTEGRITY. (23) VIOLATION ABATED. CIELINGS HAVE BEEN REPAIRED. (24) VIOLATION NOT ABATED. WINDOW COVERSION TO SMALLER WINDOW HAS NOT BEEN ADDRESSED. OWNER MUST APPEAL TFD AND DSD, LIFE SAFETY ISSUE. (25) VIOLATION NOT ABATED. HAZARDOUS ELECTRICAL HS NOT BEEN ADDRESSED. (26) VIOLATION NOT ABATED. THE UNION LOCATED INSIDE THE HOUSE HAS BEEN ELIMINATED BUT THE FLEX LINE WHICH PENETRATES THE WALL HAS NOT BEEN ADDRESSED. NEW VIOLATION; THE ROOF EDGING IS LACKING DUE TO THE REPLACEMENT OF THE FACIA. D) UNIT-D: THE UNIT APPEARS TO BE OCCUPIED AS INDICATED BY THE NIEGHBORS BUT NO ONE WAS HOME. LETTER LEFT ON DOOR RE INSPECTION. E) UNIT-E: (28) VIOLATION NOT ABATED. THE OWNER ATTEMPTED TO STABILIZE THE PORCH BY REPLACING STRUCTURAL MEMBERS WHICH AGAIN REQUIRE PERMITS. THE PORCH SHOULD BE EITHER REMOVED OR PERMITTED. THE GAS LINES AND THE WATER HEATER, STILL HAVE NOT BEEN PERMITTED. (29) VIOLATION ABATED. COOLING FIXED. (30) VIOLATION APPEALED AND GRANTED. (31) VIOLATION NOT ABATED. EXTENSION CORDS STILL BEING USED AND LIGHT FIXTURE STILL NOT FIXED. (32) VIOLATION NOT ABATED, NO SMOKE DETECTORS. (33) VIOLATION ABATED. (34) VIOLATION ABATED RE GENERAL DILAPIDATION.
12/13/2004 INITIAL CODE VIOLATION JHURD Correction Required UNIT A; ISSUE'S ON NOTICE AND ORDER NOT COMPLETED. 1) LIVING ROOM WINDOW BROKEN. 2) ADDITION TO EAST SIDE, NO PERMITS SECURED. 3) CONVENIENCE OUTLETS AND SWITCH PLATES MISSING. 4) CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST, 3-PRONG CONVENIENCE OUTLETS WITH 2-WIRE SYSTEM. 5) ADDED 4-GANG ELECTRICAL BOX IN KITCHEN, PERMIT HAS NOT BEEN SECURED. 6) ADDED ROOM TO EAST SIDE NO PERMITS, WALLS OPEN AND EXPOSING ALL INSULATION, FIRE HAZARD. 7) EXPOSED ELECTRICAL WIRING. 8) HOLES IN DRYWALL 9)REPLACEMENT OF HEATER, NO PERMITS. 10) ELECTRICAL METER SERVICE SHOWS ADDED ELECTRICAL CIRCUITS, NO PERMITS. NEW ISSUES; 1) CONVENIENCE OUTLET NOT PROPERLY SECURED TO WALL. 2) LIGHT FIXTURES MISSING PROTECTIVE COVERINGS. 3) CAR MOTOR OIL BEING STORED UNDER KITCHEN SINK. 4) ADDED 3-GANG ELECTRICAL BOX IN LEIU OF ONE, MISSING COVER PLATE ON FRONT. 5) ADDITIONAL CONVENIENCE OUTLETS ADDED. ISSUES ON COURT ORDER; UNIT B, ISSUES ON NOTICE AND ORDER: 1) COOLER STAND HAS BEEN INSTALLED IN A HAZARDOUSLY MANNER. 2) NATURAL GAS LINE HAS BEEN RELOCATED, PERMIT HAS NOT BEEN SECURED FOR RELOCATION. 3) LIVING ROOM WINDOW BROKEN. BEDROOM WINDOW BROKEN. 4) STRUCTURE HAS HOLE IN WALL, FRONT DOOR DOES NOT SEAL PROPERLY. 5) ADDITION ADDED TO FRONT FOR STORAGE, PERMIT HAS NOT BEEN SECURED. 6) ELECTRICAL WORK HAS BEEN DONE, NO PERMITS HAS BEEN SECURED. CONVENIENCE OUTLETS INSTALLED ALSO, 3-PRONG TYPE ON 2-WIRE SYSTEM, ADDED CIRCUITS. 7) ADDITION OF CLOTHES CLOSET, NO PERMITS, WALLS HAS NOT BEEN COMPLETED, EXPOSED INSULTION, FIRE HAZARD. 8) RESIDENTS HAZARDOUSLY USING EXTENSION CORDS IN LIEU OF PERMANENT WIRING DUE TO LACK OF CONVENIENCE OUTLETS. EXTENSION CORDS SHOWING OPEN AND UNSECURED CONNECTIONS. 9) HOT WATER TANK HAS BEEN INSTALLED NO PERMIT HAS BEEN SECURED. NEW ISSUES, UNIT B: 1) COOLER ELECTRICAL WIRING DETERIORATED AND FRAYED. 2) WOOD WINDOW FRAME DETERIORATED AND ROTTED TO APOINT OF FALLING APART. NEW ISSUES- UNIT B: HEATER CABINET COMBUSTABLE AREA RUSTED AND HAS NOT BEEN MAINTAINED, DIRTY,

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T01VL02233
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
03/11/2005 CONTACTED BY PHONE
08/15/2001 NOTICE AND ORDER ISSUED
09/24/2004 SITE VISIT/INSPECTION MADE. SEE INSPECTION RESULTS AND NOTATIONS FOR SPECIFIC INFORMATION.