Inspection History Details
Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2004 | INITIAL CODE VIOLATION | Correction Required | UNIT A; ISSUE'S ON NOTICE AND ORDER NOT COMPLETED. 1) LIVING ROOM WINDOW BROKEN. 2) ADDITION TO EAST SIDE, NO PERMITS SECURED. 3) CONVENIENCE OUTLETS AND SWITCH PLATES MISSING. 4) CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST, 3-PRONG CONVENIENCE OUTLETS WITH 2-WIRE SYSTEM. 5) ADDED 4-GANG ELECTRICAL BOX IN KITCHEN, PERMIT HAS NOT BEEN SECURED. 6) ADDED ROOM TO EAST SIDE NO PERMITS, WALLS OPEN AND EXPOSING ALL INSULATION, FIRE HAZARD. 7) EXPOSED ELECTRICAL WIRING. 8) HOLES IN DRYWALL 9)REPLACEMENT OF HEATER, NO PERMITS. 10) ELECTRICAL METER SERVICE SHOWS ADDED ELECTRICAL CIRCUITS, NO PERMITS. NEW ISSUES; 1) CONVENIENCE OUTLET NOT PROPERLY SECURED TO WALL. 2) LIGHT FIXTURES MISSING PROTECTIVE COVERINGS. 3) CAR MOTOR OIL BEING STORED UNDER KITCHEN SINK. 4) ADDED 3-GANG ELECTRICAL BOX IN LEIU OF ONE, MISSING COVER PLATE ON FRONT. 5) ADDITIONAL CONVENIENCE OUTLETS ADDED. ISSUES ON COURT ORDER; UNIT B, ISSUES ON NOTICE AND ORDER: 1) COOLER STAND HAS BEEN INSTALLED IN A HAZARDOUSLY MANNER. 2) NATURAL GAS LINE HAS BEEN RELOCATED, PERMIT HAS NOT BEEN SECURED FOR RELOCATION. 3) LIVING ROOM WINDOW BROKEN. BEDROOM WINDOW BROKEN. 4) STRUCTURE HAS HOLE IN WALL, FRONT DOOR DOES NOT SEAL PROPERLY. 5) ADDITION ADDED TO FRONT FOR STORAGE, PERMIT HAS NOT BEEN SECURED. 6) ELECTRICAL WORK HAS BEEN DONE, NO PERMITS HAS BEEN SECURED. CONVENIENCE OUTLETS INSTALLED ALSO, 3-PRONG TYPE ON 2-WIRE SYSTEM, ADDED CIRCUITS. 7) ADDITION OF CLOTHES CLOSET, NO PERMITS, WALLS HAS NOT BEEN COMPLETED, EXPOSED INSULTION, FIRE HAZARD. 8) RESIDENTS HAZARDOUSLY USING EXTENSION CORDS IN LIEU OF PERMANENT WIRING DUE TO LACK OF CONVENIENCE OUTLETS. EXTENSION CORDS SHOWING OPEN AND UNSECURED CONNECTIONS. 9) HOT WATER TANK HAS BEEN INSTALLED NO PERMIT HAS BEEN SECURED. NEW ISSUES, UNIT B: 1) COOLER ELECTRICAL WIRING DETERIORATED AND FRAYED. 2) WOOD WINDOW FRAME DETERIORATED AND ROTTED TO APOINT OF FALLING APART. NEW ISSUES- UNIT B: HEATER CABINET COMBUSTABLE AREA RUSTED AND HAS NOT BEEN MAINTAINED, DIRTY, |
|
| 09/30/2004 | INITIAL CODE VIOLATION | Correction Required | INITIAL INSPECTION UNIT (E) DONE 9-22-04. SITE INSPECTION WAS DONE ON UNIT UNDER A WARRENT FROM THE CITY OF TUCSON; INSIDE THE UNIT IT WAS FOUND TO BE VERY DIRTY, THE CURRENT TENANT IS WHEEL CHAIR BOUND AND UNABLE TO MAINT. THE UNIT. REVIEW OF THE CURRENT HEATING SYSTEM (WALL MOUNT UNIT) HAS BEEN FOUND VERY RUSTY AND FILLED WITH DIRT, THIS SYSTEM CAN NOT OPERATE IN A SAFE MANNER DUE TO THE LONG TERM LACK OF MAINT. THE UNIT WAS FOUND TO LACK THE REQUIRED SMOKE ALARMS IN ANY ROOM. THE FRONT DOOR IS MISSING THE SWEEP AND ALL WEATHER SEALS THAT ARE REQUIRED. THE SMALL HALLWAY NEAR THE RESTROOM HAS BEEN FOUND TO HAVE 110 ELECT. WIRES SHOWING TO THE OUTSIDE OF WALL AND UNPROTECTED. THE SAME HALL -LIVING ROOM AND BATHROOM HAVE BEEN FOUND TO HAVE PLASTER DAMAGED WALLS. THE RETURN AIR GRILLE FROM THE COOLER HAS BEEN FOUND LEAKING WATER INTO THE UNIT AND THE GRILLE IS ALSO FOUND RUSTY. THE KITCHEN FLOOR WAS FOUND TO BE MISSING 75% OF THE FLOOR TILES. THE BATHROOM TOLIET HAS BEEN FOUND LEAKING AT THE WATER LINE CAUSING WATER DAMAGE TO THE WALL. THE CURRENT TENANT IS UNABLE TO MOVE FREE INSIDE THE UNIT DUE TO HIS WHEEL CHAIR. |
|
| 09/30/2004 | INITIAL CODE VIOLATION | Correction Required | INITIAL INSPECTION UNIT (D) DONE 8-27-04 SITE INSPECTION WAS DONE ON AUG.27.2004 TENANT ALLOWED INSPECTOR CRAIG INSIDE UNIT WHILE GIVING OK FOR DNR TO INSPECT ON A LATER DATE. WHILE INSIDE THE UNIT THE TENANT STATED THAT THE HEATING SYSTEM WAS NOT WORKING PROPER AND THE BURNER WOULD GO OUT ALL THE TIME, I DID LOOK AT THE HEATER AND FOUND THAT IT LACK TOTAL MAINT. AND WOULD NOT BE ABLE TO OPERATE IN A SAFE MANNER. THE TENANT ALSO STATED THAT THE COOLER ON THE ROOF LEAKED WATER INTO THE UNIT. I FOUND A BROKEN WINDOW IN THE LIVING ROOM AND BATH ROOM. THERE WAS NO SMOKE ALARM FOUND INSIDE THE UNIT AT THAT TIME. THE TENANT ALSO STATED THAT THERE WAS A SINK PROBLEM , THAT WAS NOT INSPECTED AT THE TIME. |
|
| 09/30/2004 | INITIAL CODE VIOLATION | Correction Required | INITIAL INSPECTION UNIT (C) DONE 9-22-04 SITE INSPECTION WAS DONE UNDER A WARRENT FROM C.O.T. TENANT WAS NOT HOME AT UNIT C TPD DID ALLOW DNR TO ENTER UNDER WARRENT AND THE TENANT ALLOWED TPD TO ALLOW DNR TO ENTER WHILE THEY WERE GONE.THE FOLLOWING ISSUE'S WERE FOUND WHILE INSIDE AND THE OUTSIDE OF UNIT. BROKEN FRONT WINDOW. FRONT CLOSET BUILT OVER FRONT DOOR W/O PERMITS, BEING APPROX 6X4X8' IN SIZE, THIS IS NOT PART OF THE OLD BUILDING, THE UNIT WAS ONCE TWO UNITS AND NOW IS ONE LARGE UNIT. NO SMOKE ALARMS. PLASTER DAMAGE IN ALL ROOMS. ROOF LEAKING INTO BEDROOM. WINDOW FRAME IN BEDROOM ROTTED. WATER LEAKING INTO WINDOWS CAUSING PLASTER DAMAGE AT WALLS. ROACHES AND ANTS FOUND IN UNIT. IMPROPER GAS SHUT-OFF TO KITCHEN STOVE. HEATER DIRTY AND NOT MAINTAINED IN A SAFE MANNER. BROKEN FLOOR TILES IN BATHROOM. TOLIET TANK MISSING TOP OR COVER. SHOWER STALL MISSING WATER CONTROLS-BROKEN. TENANT USING ELECT. DROP CORD FOR CLOSET ELECT. SUPPLY. REAR YARD COVERED WITH TRASH AND JUNK. ADDED ELECT.CIRCUITS TO REAR OF UNIT W/O PERMITS. LARGE SEWER PIPE BREAK IN REAR OF UNIT-NOTICE WAS GIVEN AT SITE-ABATED. DONE W/O PERMITS. |
|
| 09/21/2004 | INITIAL CODE VIOLATION | Correction Required | ||
| 07/25/2001 | INITIAL CODE VIOLATION | Correction Required | Initial Inspection 07/25/2001 History: Unit A refused entry requiring warrant. Exterior found large addtion on east side with evidence of plumbing. Unit B: Allowed entry with violations pertaining to work w/o permits re gas,water heater, weather protection,and electrical violations. This unit is occupied by the maintenance man. Unit C: Tenants were not home and notification was posted on front door and given to maintenance man to relay info. Exterior review found extensive exterior structual cracks, weather protection prblems, electrical hazards. Unit D: Unit is vacant. Unit E: Occupant was not home. According to maint man occupant is in hospital and may return tomarrow. Will return. Note posted on front door. NOTE: Inspections were conducted by Rick Saldate, Richard Vidal of DSD and Glenn D'Auria of TFD. TPD served warrant. |