EMER - UNIT ON BLDG 924 (NOT 9024) THIS COMPLEX HAS AN ADDRESSING PROBLEM - TFD requesting building safety for broken fire sprinkler line causing flooding and collapsed ceilings - MAIN CASE ACTIVITIES TO BE LOGGED UNDER CE-VIO0526-02078

Entered Date:

05/08/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Received
Case Number: CE-VIO0526-02079
Case Description: EMER - UNIT ON BLDG 924 (NOT 9024) THIS COMPLEX HAS AN ADDRESSING PROBLEM - TFD requesting building safety for broken fire sprinkler line causing flooding and collapsed ceilings - MAIN CASE ACTIVITIES TO BE LOGGED UNDER CE-VIO0526-02078
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/08/2026 COT - ENFC - Code Enforcement - Initial In Violation Arrived on scene at 742 PM and TFD had already left the scene. Contractor was cutting out flooring in Unit 934 when pieces of wood struck the fire sprinkler water supply line and ruptured the pipe. This caused the ceiling of Unit 924 to collapse and the unit was flooded, and there is approximately more than an inch of standing water in the unit. Kitchen light fixture collapsed, wiring in ceiling wet. There is a second light fixture to the pantry that is also likely wet. Drywall is wet in the kitchen soffit. Light switch box in bedroom across from kitchen has water in it. Checked switch outside bathroom, inside bathroom, and GFCI in bathroom abutting the kitchen and none had water in them. The electrical panel does not have any apparent water in it and breakers appear dry. It is unclear if wiring behind walls have come in contact with water. Drywall is wet throughout the unit. Kustom Restoration arrived on scene and began extracting water. Aforementioned light switch shall be replaced. A licensed electrician shall review the electrical system of the entire unit. Power was isolated to unit at main disconnect and locked off by property management. Unit has been condemned due to electrical. Permits required for repairs. -VM

Documents

File Name Document Type  
CE-VIO0526-02079 01 EAOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0526-02079 02 NOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0526-02079 03 NAO SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-05-08 CE-VIO0526-02079.PDF DOCUMENTS VIEW
IMG_0645.JPG DOCUMENTS VIEW
IMG_0646.JPG DOCUMENTS VIEW
IMG_0647.JPG DOCUMENTS VIEW
IMG_0648.JPG DOCUMENTS VIEW
IMG_0649.JPG DOCUMENTS VIEW
IMG_0650.JPG DOCUMENTS VIEW
IMG_0651.JPG DOCUMENTS VIEW
IMG_0652.JPG DOCUMENTS VIEW
IMG_0653.JPG DOCUMENTS VIEW
IMG_0654.JPG DOCUMENTS VIEW
IMG_0655.JPG DOCUMENTS VIEW
IMG_0669.JPG DOCUMENTS VIEW
IMG_0672.JPG DOCUMENTS VIEW
IMG_0676.JPG DOCUMENTS VIEW
IMG_0677.JPG DOCUMENTS VIEW