Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

Received

Type:

EMER - TPD Emergency callout for occupied previously condemned home, work without permits including to electrical, addition underneath electric drop and addition at far west side of structure
Address:

Entered Date:

04/28/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Received
Case Number: CE-VIO0426-01858
Case Description: EMER - TPD Emergency callout for occupied previously condemned home, work without permits including to electrical, addition underneath electric drop and addition at far west side of structure
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/28/2026 COT - ENFC - Code Enforcement - Follow Up In Violation 1234 pm - Verified all doors are locked/secured, window at rear is boarded, there is no one on site at this time. -VM
04/28/2026 COT - ENFC - Code Enforcement - Initial In Violation Called out to site by TPD due to a previously condemned home being occupied. Arrived and found the front door is ajar, owner came outside and states he is using multiple generators to power the structure. He allowed access to property, I verified the main electric meter serving the home is off and a second electric meter and panel on second unit is missing the meter and the dead front. Home was previously condemned on or around 03/06/2026 under case CE-VIO0226-00959. In the area of the electric meter, on the west side of the main home, there is an addition to the roof that compromises the required 8 foot distance between the roof and the electric drop. This may need to be addressed prior to reconnecting power. In addition, there is many instances of electrical work done without permits including romex lines ran out of the electric panel and exposed under the aforementioned roof addition that is powering electrical outlets, switches, and light fixtures. There is some type of addition to the structure at the southwest portion of the structure built out of wood and appears to be a staircase to the roof. The yard of the property is full of excessive trash and debris. Issued an order to vacate to the owner and ordered the property secured. -VM

Documents

File Name Document Type  
CE-VIO0426-01858 01 EAOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0426-01858 02 NAO SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-04-28 CE-VIO0426-01858.PDF DOCUMENTS VIEW
IMG_0382.JPG DOCUMENTS VIEW
IMG_0383.JPG DOCUMENTS VIEW
IMG_0384.JPG DOCUMENTS VIEW
IMG_0385.JPG DOCUMENTS VIEW
IMG_0386.JPG DOCUMENTS VIEW
IMG_0387.JPG DOCUMENTS VIEW
IMG_0388.JPG DOCUMENTS VIEW
IMG_0389.JPG DOCUMENTS VIEW
IMG_0390.JPG DOCUMENTS VIEW
IMG_0391.JPG DOCUMENTS VIEW
IMG_0392.JPG DOCUMENTS VIEW
IMG_0393.JPG DOCUMENTS VIEW
IMG_0394.JPG DOCUMENTS VIEW
IMG_0395.JPG DOCUMENTS VIEW
IMG_0396.JPG DOCUMENTS VIEW
IMG_0397.JPG DOCUMENTS VIEW
IMG_0398.JPG DOCUMENTS VIEW
IMG_0399.JPG DOCUMENTS VIEW