Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Search

Parcel Attributes

Parcel14029196A
JurisdictionTucson, Pima County
City of Tucson ZoningI-1
Tucson WardWard 5
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Parcel Attributes Issue?

Historic Records Requests

Address: 6200 S HEMISPHERE PL
Date - 08/16/2026 11:51 p.m.
Total Number Of Historic Records Requests - (2)
Name Action
Address: 6200 S HEMISPHERE PL - Doc Type: CERT OF OCC VIEW
Address: 6200 S HEMISPHERE PL - Doc Type: CERT OF OCC VIEW

Annexations & Original City Zoning (OCZ)

Address: 6200 S HEMISPHERE PL
Date - 08/16/2026 11:51 p.m.
Total Number Of Annexations & Original City Zoning (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C15-88-01 Country Club - Valencia 7025 7090

Special Development Requests & Requirements

Address: 6200 S HEMISPHERE PL
Date - 08/16/2026 11:51 p.m.
Total Number Of Special Development Permits - (1)
Activity Number Status Apply Date Expired Date Unit Type Description
H000003764 CLOSED 12/02/2011 N/A Historical Information

Permits

Address: 6200 S HEMISPHERE PL
Date - 08/16/2026 11:51 p.m.
Total Number Of Permits - (21)
Permit Status Apply Date Expired Date Unit Type Description
TR-UTL-1024-02004 Complete 10/17/2024 05/04/2025 Right-of-Way (ROW) - Utility P.122870A (KAHNA) - BORE 4,372' & TRENCH 149’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (18) HANDHOLES & (18) PEDESTALS.
DP15-0080 Complete 05/12/2015 02/10/2016 Development Package SITE IMPROVEMENTS
T04AN00903 ISSUED 09/22/2004 N/A ADDRNEW
T04CM04846 C OF O 11/02/2004 12/01/2007 COMBO NEW:SCHOOL
T06BU01891 FINAL 07/31/2006 02/12/2007 TEMP-FBB TEMP CONSTRUCTION TRAILER
T06BU02726 EXPIRED 11/17/2006 05/28/2007 SPKLR FIRE SPLKR: NEW 320' UNDERGROUND
T06EX00971 CLOSED 09/08/2006 11/07/2006 EXCAV TRENCH 436'D(INSTALL 8" MAIN 6" FIRE HYDRANT)
T07BU00104 FINAL 01/16/2007 11/04/2007 SPKLR INSTALL 364 NEW FIRE SPRINKLERS
T07BU00430 FINAL 02/23/2007 11/13/2007 BUILD FIRE ALARM FOR REMODEL OF SCHOOL
T07BU00443 FINAL 02/28/2007 11/13/2007 BUILD INSTALLATION OF KITCHEN FIRE SYSTEM
T07EX00196 CLOSED 03/20/2007 05/19/2007 EXCAV 2 DRIVEWAY ENTRANCES
T15CM05733 WITHDRWN 08/17/2015 N/A COMBO NEW PEDESTAL AND OUTDOOR LIGHTING
T15EX01390 FINAL 05/30/2015 07/31/2015 EXCAV INSTALL NEW CURB RETURNS AND ASPHALT APPROACH IN THE RIGHT-OF-WAY FOR NEW PARKING LOT PER THE APPROVED PDSD PLAN.
T15EX02059 FINAL 07/06/2015 09/04/2015 EXCAV BORING UNDER HEMISPHERE LOOP FOR TEP WORK ORDER # 293736
T15TC01355 EXPIRED 06/01/2015 N/A BARRICAD INSTAL NEW CURB RETURNS AND DRIVEWAY
T15TC01628 FINAL 07/06/2015 N/A BARRICAD BORING UNDER HEMISPHERE LOOP FOR TEP
T16EX00543 FINAL 02/23/2016 04/23/2016 EXCAV 10 LF IN FRONT OF ADDRESS IN THE ASPHALT TO RENEW LEAKING SERVICE; TW CREWS WIL BE USING UTILITY TRUCKS AND SAFETY CONES. WORK ORDER # 1601599
T16FC00204 FINAL 11/03/2016 07/17/2017 FIRECONS Install a cell communicator to monitor existig fire panel
T16RW00131 FINAL 06/21/2016 08/20/2016 ROW STARTING AT COX PEDESTAL IN FRONT OF 6218 S SUNRISE VALLEY DR, TRENCH/BORE NORTH 62', THEN TRENCH/BORE WEST 103', THEN TRENCH/BORE SOUTH 101', THEN TRENCH/BORE 106' OUT OF ROW WORK HOURS: 9A - 3:30P
T18CM04807 FINAL 06/20/2018 08/24/2019 COMBO INSTALL SHADE STRUCTURE MOUNTED SOLAR PV SYSTEM
T18RW05690 FINAL 12/28/2018 05/04/2019 ROW Starting on the N/W corner of E. Hemisphere Loop and S. Hemisphere Pl at Cox existing Vault, pull through existing conduit going S. for 75' then west 1195' to Cox Existing vault. From Vault trench /bore N. 713' then East 50' to out of row ,placing 3x3x3 potholes where needed along the way.

Plans

Address: 6200 S HEMISPHERE PL
Date - 08/16/2026 11:51 p.m.
Total Number Of Plans - (1)
Plan Number Status Application Date Exp Date Unit Type Description
T06PI00041 FINAL 08/08/2006 09/16/2007 PAVING -- 205 SUNNYSIDE ELEMENTARY SCHOOL CUL-DE-SAC PIA PLANS Gallego Elementary School