Permit Review Detail
Review Status: Active
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM06960
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2022 | ANY | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Active | |
| 09/12/2022 | VFLORES1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | Please contact Pima County Addressing to have suites added into the system Phone #:520-724-9512 Email: addressing@pima.gov |
| 09/14/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
| 09/19/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Plans shall show the occupancy types and whether or not they are separated Occupant load shall be provided on the drawings Plans shall show deferred fire sprinkler and fire alarm drawings Building heights shall be shown on the drawings. If the building exceeds 35' the building shall be tested by PCWIN and report provided to TFD Questions: Jennifer Peel-Davis Tucson Fire Department Fire Plans Examiner Fire Inspector I, II and Fire Alarm Plans Examiner Jennifer.Peel-Davis@Tucsonaz.gov Desk: 520-837-7033 |
| 09/22/2022 | SAMUEL ROGERS | ZONING | REVIEW | Approved | |
| 09/27/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM06960 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Mechanical Drawing M6.1 shows Roof Top Units Schedule with RTU-1 and RTU-2, each weighing 750 pounds. No structural Calculations are provided justifying the existing roof structural members are adequate to support these RTU’s. Submit Structural Calculations justifying the adequacy of the Roof Joists/Roof Girders to transfer the loadings to the Structural Columns. 2. Provide details if any reinforcing of Steel Joists is needed for the off panel point loadings on the Steel Joists. 3. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. BUILDING REVIEW COMMENTS: Denied 1. Provide the area of the tenant space. Estimations are not permitted. 2. Provide accurate occupant load calculation and plumbing fixture calculations. On the cover page it states that an F-1 occupancy is being used and another page states a S-1 occupancy is being used. It's understood that these are spec suites with no contracted tenants. However, it's consistency is important. Include the warehouse/storage space into the occupant load calculations. 3. Exiting through F-1/S-1 space would not be permitted as it is a potential higher hazard depending on tenant processes. This exit signage may need to be removed. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Denied Could not determine any differences from an earlier submittal. Same issues. E4.1 ELECTRICAL SINGLE LINE DIAGRAM: Primary conductors into both 75 KVA transformers are undersized for an installed 100-amp CB per panel schedules in Sheet E5.1. E5.1 ELECTRICAL SCHEDULES: Need to perform short circuit calculations for new panels per Tucson design requirements and then call out KAIC ratings for new panels PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: 1). Need to address Building plan review occupancy related comment #2 before a complete plumbing review can be done. - IPC 403.1 2). This occupancy requires high/low drinking fountains & service sinks. or show existing location with distances to common area existing fixtures. -IPC 403.1, 403.5 update all affected pages 3). Will this coffee area have a water connection? if yes update plan page P3.0 & P6.1 with backflow device info -IPC 608.17.1.2 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 10/11/2022 | ROBERT SHERRY | WATER | REVIEW | Completed |