Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM06956
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/12/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
09/12/2022 | VFLORES1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | Please contact Pima County Addressing to have suite added into the system Phone #:520-724-9512 Email: addressing@pima.gov |
09/15/2022 | IMONSHI1 | ZONING | REVIEW | Approved | |
09/15/2022 | IMONSHI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
09/26/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM06956 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: Denied 1. Provide an updated occupant load calculation. The spaces have been reconfigured to where the occupant loads will need to be calculated. Provide an updated occupant load calculation in accordance with Section 1004. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E2.1A ELECTRICAL POWER RENOVATION PLAN - AREA A: Two sets of office furniture share the same sets of circuits in lower left of sheet. Correct if required. PLUMBING REVIEW COMMENTS: Conditionally Approved First Plumbing Review: -Each Coffee maker water connection on M3.1C Needs its own ASSE 1024 Backflow If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
10/03/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
10/11/2022 | ROBERT SHERRY | WATER | REVIEW | Completed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
10/11/2022 | VVERA1 | OUT TO CUSTOMER | Completed |