Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T22CM06674
Parcel: Unknown

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM06674
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2022 SHASEMA1 ENGINEERING REVIEW Passed
09/13/2022 STEVE SHIELDS ZONING REVIEW Approved
09/13/2022 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/16/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM06674

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. The Enercalc calculations submitted for steel angle lintel at Mechanical Penetration shows the Steel Angle Lintel failing in Bending. See page 65 of Calculations. Investigate, make revisions as needed and submit response.


BUILDING REVIEW COMMENTS:
Denied
1. Provide the over all SQ. FT. of the hospital in addition to the provided renovated area.
2. Provide an updated occupant load and it's comparison into the overall occupant load of the hospital.


MECHANICAL REVIEW COMMENTS:
Denied
1. Provide fire damper where duct penetrates roof /ceiling assembly (IMC2018,607.6) sheet M301A
2. Provide fire and smoke dampers where duct penetrates shaft sheet M301B (IMC2018,607.5.5)
3. Provide CO2 sensors and ventilation or alarm in an approved manner to nitrogen room, also provide sequence of operation for the CO2 system (IBC2018,908.7) sheet M301B



ELECTRICAL REVIEW COMMENTS
Conditionally Approved
E202 AREA A ELECTRICAL POWER PLAN: Could not locate Keynote #4.
E204 AREA B ELECTRICAL POWER PLAN: Could not locate Keynote #10.
E205 AREA C ELECTRICAL POWER PLAN: Suggestion only. Add an extra receptacle on 1 or 2 other walls in Sign Out Rooms to accommodate future furniture changes. Suggestion applies to any rooms with only 1 receptacle on a single wall.
E301 AREA A LIGHTING PLAN: Light switch control schedule has last column cut off.
E302 AREA B LIGHTING PLAN: Hallways need some exit signs.
E402 AREA C SYSTEMS PLAN: Keynote #2 shown, but only call out Keynote #1.
E801 DETAILS, SCHEDULES, & RISERS DIAGRAMS: Primary for new 225KVA transformer is undersized and may nuisance trip if it remains a 225KVA transformer. Secondary side equipment could be supported by a 150 KVA transformer per typical NEC calculations.


PLUMBING REVIEW COMMENTS:
Denied
First Plumbing Review:
1). Sinks S1 & S5 on plan pages P200B & P500 can't discharge indirectly or connect to a bldg. drain that is indirect. -IPC 802.1
2). FS-1 on plan page P500 in HCTT lab needs a trap -IPC 1002.1
3). Plumbing plans need to have a install configuration detail for the required neutralizing tanks at the S2, S2A, S7 sinks listed on P801, show the detail on P601 or P801 & show the locations of the neutralizing tanks on plan pages P200A thru P500- IPC 803.1
4). Vacuum Piping Routing continuation note on P301A needs to refer to plan page P301B not P201B. -IPC 106.3.1
5). Plan Page A701 needs to show the side wall clearances to all restroom fixtures -IPC 404.2, 405.3.1
6). Faucets with combination eye washes on plan P801 need ASSE 1071 Mixing Valves. ( this specific rating not called out in spec manual) -IPC 411.3


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
09/27/2022 ROBERT SHERRY WATER REVIEW Completed
10/03/2022 JPEELDA1 FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/03/2022 VVERA1 OUT TO CUSTOMER Completed