Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM05854
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2022 | SCABRAL1 | ENGINEERING | REVIEW | Passed | |
| 08/15/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/15/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 08/15/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/19/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | Activity Number: T22CM05854 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. 1. A500 1202.6 Please coordinate with the Mechanical Engineer to provide proper clearances for the type I hood to combustible materials and or provide protection details per the mechanical code 507.2.6 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 08/24/2022 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Reduced pressure backflow prevention assemblies are required to be installed directly after the water meter for buildings that have food service facilities. Reduced pressure backflow prevention assemblies are required to be installed in locations accessible to Tucson Water. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf |
| 08/24/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. With respect to detail 2/P1.2, all of the vents (except for vents serving interceptors located outdoors) shall rise vertically (i.e. an angle greater than 45 degrees) to at least 6" above the flood rims of the fixtures they protect prior to running horizontally. Reference: Section 905.4, IPC 2018. 2. Correct Plan Note 8 on sheet P5.0. The gas is to supply MUA-1, not RTU-2, which is a heat pump. Reference: Section 107.2.1, IBC 2018. |
| 08/25/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide structural calculations and details to show that the Type I hoods are supported from the building structure in accordance with Section 507.2.4, IMC 2018 (the hood hanging weight plus the weight of personnel working in or on the hood). Reference: Section 302.1, IMC 2018. 2. Show that combustible materials (e.g. plywood) are not located within 18" of the Type I hoods. Reference: Section 507.2.6, IMC 2018. |
| 08/29/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1 The option to use ASHRE 90.1 for energy lighting and power requires automatic control for receptacle at 50%. Please provide this information on the power and lighting plans. Show how this requirement is addressed in detail. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. |