Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM03775
Parcel: 122153510

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM03775
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/17/2022 VFLORES1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Reqs Change UNIT NUMBER FOR PROPOSED ADU IS REQUIRED.PLEASE CONTACT PIMA COUNTY ADDRESSING PH# 520-724-9512 ADDRESSING@PIMA.GOV
05/23/2022 STEVE SHIELDS ZONING REVIEW Approved
05/23/2022 SSHIELD1 NPPO REVIEW Passed
05/24/2022 SSHIELD1 ENGINEERING REVIEW Approved
06/09/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Replace the full size refrigerator with a half size for avoiding an impact fee which is applied for an ADU but not for a sleeping quarters.

Provide a panelboard clear working space of 30" wide x 36" deep, E3405.2. Remove the panel from the laundry closet.

Show all receptacle outlets located within 6’ of a sink with ground fault circuit interrupting protection, E3902.