Permit Number - T22CM03576
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM03576 Fire damage 2141 E IRENE VISTA Zoning R-1 TRANSMITTAL DATE:May 11,2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: The Pima County Assessor’s effective construction date for your building or structure is 1953. The actual construction date may be earlier. Buildings, portions of buildings or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation will be reviewed and approved by the Historic Preservation Office before a permit is issued. Demolition (Historic and Older Structures) Application and General Information may be downloaded (PDF) at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements Return completed documentation to PDSDHistoric@tucsonaz.gov. Applicant will be contacted within 5 working days if additional materials are required for review. 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. 3.COMMENT: Provide all setbacks. After reviewing the aerials it has come to my attention that the rear portion of the house was actually a porch addition, not an existing be room. Provide all the information for the porch to be converted into a bedroom. Provided in the link below is the arterial Pictometry- https://gis.pima.gov/pictometry/ipa//IPAfullnet/llviewer.aspx?lat=32.1863&lon=-110.9394 If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 05/11/2022 | PCAMARE1 | NPPO | REVIEW | Passed | |
| 05/19/2022 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: Is this for a new or existing activity application? – Please select New Application. Submission Type – Select Floodplain Use Permit. Project Name – Enter a name for your project. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.) Complete the Applicant Info. Complete the Contractor, Owner and Architect/Engineer sections as applicable. Supporting Documentation Upload – Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful. Sign the application and submit. You will be given an activity number for your submittal. Please copy and send this number back to us so we can continue the review. |
| 05/27/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM03576 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide information on the roof structure that indicates the rafter sizes, roof sheathing and the finished roofing product for the porch. Only the posts and beams are indicated in the plans on sheet 6 and there are no notes for the wall section G. BUILDING REVIEW COMMENTS: Denied 1. Indicate on the front page that all work will follow the codes and ordinances of the City of Tucson. 2. Provide a section or detail for the ADA accessible ramp showing the length of the ramp and slope as well as the required landings at the top and the bottom. Indicate type of materials to be used such as concrete and gravel base or PT wood. 3. Increase the landing size at the door to a m minimum of 60” x 60”. ANSI A117.1 405.7 requires a 60” landing minimum for the ramp in the direction of travel. When the door is subject to locking is adjacent to a ramp landing, the landing shall provide a turning space 405.7.5. MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. All bath fans will be exhausted directly to the exterior. 2018 IRC M1505.2. ELECTRICAL REVIEW COMMENTS Denied 1. Clarify that the CO detectors are combination CO and Smoke detectors or just CO. The electrical symbols list only indicates CO. If this is not a combo unit, add smoke detectors to these locations as well. 2. Indicate an exterior outlet within 25 feet of the service panel. There is an outlet indicated in the electrical notes sheet 4 for under the service panel however it is not shown on the plans 3. This appears to be a new electrical service, indicate a Ufer ground into the building foundation rebar will be provided. 2017 NEC 250.52 (A)(3). 4. It appears that the can lighting in the laundry room will interfere with the attic access. Modify this area by moving the lighting or the access location. 5. Provide light in attic at the attic access point. 2017 NEC 210.70. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |