Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM03058
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/26/2022 | GPENNIN1 | ENGINEERING | REVIEW | Passed | |
| 04/26/2022 | GPENNIN1 | ZONING | REVIEW | Approved | |
| 04/26/2022 | GPENNIN1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/11/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM03058 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Refer to Mechanical Drawings M1.RA and M1.RB. The Drawing shows 2 new 6.5-ton A/C units and 2 New 3 ton Condenser units on existing roof. Provide structural calculations verifying the adequacy of the existing roof members to support the new units. All calculations are to be sealed and signed by the PE registered in State of Arizona. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. Approved/Subject to field approval. ELECTRICAL REVIEW COMMENTS Conditionally Approved Engineer’s seal is shown as expired, should be updated for future submittals E1.1A: One of the Keynote #7 notes seems to be referencing a large (112KVA?) Transformer (Mislabeled Keynote #8?) and not a PDU as shown by the other Keynote #7. Probably should be Keynote #8 as it is not used. E5.2: Keynote #3 not used/shown. Could be one of the Keynote #4 notes. E6.2: Should show Mini Split fan coil loads in Panel L/B-6 EM. PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: 1). Label the DHWR piping on plan pages M3.0 & M3.1A. -IPC 106.3.1 2). Spec book page 110553-7 Showa compressed gases, the piping illustrations of these gases not shown within the plumbing plans? IPC A106.3.1 3). Label vent for office sink on plan page M.3.1A As AAV or show vent termination. 0IPC 901.2.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 05/17/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/25/2022 | JPEELDA1 | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/25/2022 | VVERA1 | OUT TO CUSTOMER | Completed |