Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM02945
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/25/2022 | WBERGER1 | ZONING | REVIEW | Approved | |
| 04/25/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 04/25/2022 | WBERGER1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 04/27/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Plans shall have a cover sheet that includes but not limited to: The scope of work Code references Occupancy type Occupant load Type of construction If the building has a fire sprinkler and or fire alarm system Plans shall show an egress plan for the new spaces that also indicates the travel distances Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 05/03/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 05/09/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide calculations to verify that adequate ventilation will be provided for the new use of the space. Reference: Section 403.3.1.1, IMC 2018. 2. Clarify the operation of the restroom exhaust fan. Provide a minimum exhaust flow rate of 50 CFM per water closet or urinal if the exhaust is continuous, 70 CFM if the exhaust is intermittent. Reference: Section 403.3.1.1 and Table 403.3.1.1, IMC 2018. |
| 05/09/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide tempered water for the public restroom lavatory using an approved device conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2018. 2. Provide a vent for the water closet. A common vent is limited to serving two traps or trapped fixtures. Reference: Sections 901.2.1 and 911.1, IPC 2018. |
| 05/09/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/17/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1. Are the 2x4 lay-in luminaires all existing? If not, provide compliance with the 2018 IECC. 2. Designate a branch circuit and panel for the new tankless hot water heater, and verify the additional load is within the panels capacity. 3. Provide GFI protection for restroom receptacle. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. |