Permit Number: T22CM02217
Parcel: 130103130

Address:
3225 E 30TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM02217
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/07/2022 CVASQUE2 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Reqs Change There are no unit numbers at 3225 E 30th st. Owner must contact Pima County Development Services to add unit for new ADU.
10/10/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
10/14/2022 WBERGER1 ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Planner

PROJECT: T22CM02217
3225 E 30th St - R-1
ADU (2nd review)

TRANSMITTAL DATE: October 14, 2022

COMMENTS: The following comments are relative to a Board of Adjustment variance (UDC 3.10.3) or a Design Development Option (DDO) (UDC 3.11.1).

1. This comment was not addressed. Per UDC Article 6.6.3.B.5, for lots less than 6,500 square feet in size, the accessory dwelling unit is limited to 650 square feet of gross floor area. For lots equal to or greater than 6,500 square feet, the accessory dwelling unit is limited to 10% of the lot size, not the exceed 1,000 square feet of gross floor area. The proposed accessory dwelling unit exceeds the allowed 10% of total size. A Board of Adjustment variance will be required.

2. This comment was not addressed. Include the laundry and bathroom additions as depicted in T22CM02118 in the lot coverage calculation for this specific plan set.

3. Add a general note on the site plan stating the accessory dwelling unit will be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code to comply with UDC 6.6.3.B.3.

4. Per UDC 6.4.5.B, setbacks are measured between the property line to the face of each exterior building wall at the wall's highest point. The minimum required side perimeter yard setback is the greater of 6'-0" or 2/3 the height of the exterior building wall (Table 6.3.2-A). Based on a wall height of 11'-11", measured from design grade to the wall's highest point, the minimum required setback to the east lot line is approximately 7'-11"; proposed is 7'-6". A Design Development Option application must be submitted and approved to reduce the required setback to the east lot line. If a variance is pursued for comment 1, this setback reduction may be included within the variance process.

Contact Mark.Castro@tucsonaz.gov if you have any questions about the variance or DDO process.

If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.