Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM01851
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 05/05/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM01851 – DP22-0040 3309 S 12th Ave – C-3 Expansion of Auto Body Repair (2nd Review) TRANSMITTAL: May 5, 2022 This site is located in the C-3 zone (UDC 4.7.22). Trade Service and Repair: Major is a permitted use in this zone (Table 4.8-4). See Use-Specific Standard 4.9.4.X.1. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per TABLE 6.3-4.A: DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES, C-3 ZONE: Nonres Use to a Res Zone the required perimeter yard setback is 1½(H), (H) = Height of the proposed exterior building wall 1. Based on an exterior building wall height of 19’-0” the required perimeter yard setback from the proposed expansion to the east property line is 28.5’, proposed setback is 6.5’. A Design Development Option (DDO) must be submitted and approved to reduce the required setback to the east property line, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. The 18’-0” height shown on DP22-0040 is not accurate and will affect the DDO requirements. 2. Zoning has reviewed the building plan for compliance with DP22-0040 and although the plans appear to match Zoning cannot approve the building plan until the DP is approved. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 05/06/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Approv-Cond | Activity Number: T22CM01851 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved 1. The stamp of the registered design professional indicates that these drawings are not for construction. Remove this statement from plans before issuing the permit. BUILDING REVIEW COMMENTS: Conditionally Approved 1. The stamp of the registered design professional indicates that these drawings are not for construction. Remove this statement from plans before issuing the permit. MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. The stamp of the registered design professional indicates that these drawings are not for construction. Remove this statement from plans before issuing the permit. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Conditionally Approved 1. The stamp of the registered design professional indicates that these drawings are not for construction. Remove this statement from plans before issuing the permit. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 05/10/2022 | JVINCEN1 | FIRE | REVIEW | Approved |