03/23/2022 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Replacement of evaporative cooling units with air conditioning units in R2, R3, and R4 occupancies requires drawings sealed by an Arizona Registrant. A heating/cooling load calculation will be required to justify the capacities of the units being installed (Sections R403.7, IECC 2018). The units themselves will also have to comply with Sections R403.1 and R503.1.2, IECC 2018 for efficiency, controls, and ductwork. As new work, the dwelling units are required to meet the current ventilation requirements shown in Section 403.3.2, IMC 2018. A test and balance report is required to verify that the ventilation air flow rates comply with the code requirements.
04/07/2022 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the electrical plan review comments and provide a written response.

1. Provide complete electrical plans. Show the location of the existing breaker panels being replaced and the new location.

2. Show detailed wiring methods for the new AC units. Include load calculations of the panels for the increased electrical load associated with the AC unit installations.

3. Provide manufacture specifications of the new AC units to verify power ratings.

This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered Electrical design professional. Provide complete electrical plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.

Ref; 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements