Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM00861
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/22/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 02/28/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00861 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Provide existing square footage. 2. Provide existing occupant load and new occupant load. MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied First Review: 1). Sanitary venting for new plumbing fixtures P1,P2,P4.P5,P6,P7 are not illustrated or notated on plan pages P2.01 & P2.02 -IPC A106.3.1 2). Nutri room isometric detail #3 on plan page P2.01 has sink mis-labeled, should be P5. -IPC A106.3.1 3). Drains for ice machines on plan pages P2.01 & P2.02 are not illustrated or notated. Also a waste receptor is not listed on plan pg. P5.01. -IPC 802.1.3 4). Label the P8 dialysis box on plan page P2.02 rooms 74008, 74009. -IPC A106.3.1 5). Demo plan keynote symbols 4 & 9 in patient room 74009A don't correlate with demo keynote legend on plan pg. P2.02 - IPC A106.3.1 6). Demo Keynote symbols 7 & 12 in patient room 74008A don't correlate with demo keynote legend on plan pg. P2.02 -IPC A106.3.1 7). Demo plan keynote symbol 8 in patient room 74034A doesn't correlate with demo keynote legend on plan pg. P2.02 -IPC A106.3.1 8). Demo Keynote symbol 6 for room 74019A doesn't correlate with Demo keynote legend on plan pg. P2.02 -IPC A106.3.1 9). Keynote symbol 2 in front of patient rooms 64003 & 64004 should be keynote symbol 3. Update plan page P3.01 10). Missing med gas alarm panel on plan pg. P3.02 across from nurses' station on side near Room 74024. NFPA 99 5.1.9.2.1 (2) 11). illustrate the med gas piping at this time for rooms 64015, 64015,74008,74009 on plan pages P3.01 & P3.02. -IPC A106.3.1 12). Lavs need ASSE 1070 mixing valves update fixture specs on plan page P5.01. -IPC 419.5 13). Plan page P0.02 Med Gas Notes references NFPA 99 2012, The 2018 International Plumbing Code Chapter 15 References to use NFPA99 2018 |
| 03/05/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 03/08/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/08/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 03/08/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/08/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |