Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM00621
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00621 5755 S Houghton Rd – PAD-12 Medical Service Major (2nd Review) TRANSMITTAL: April 20, 2022 Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the PAD-12. Medical Service Major is a permitted use in this PAD. 1. Zoning has reviewed the building plans for compliance with DP21-0302, although the plans appear to match what was shown on the DP, until the DP is approved Zoning cannot approve the building plans. 2. COMMENT: Provide documentation from that the requirements of PAD-12 Section C-12 have been complied with. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. |
| 04/20/2022 | DBENOIT1 | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00621 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved This set is Envelope and Structure only. Mechanical plans will be submitted mid-April per engineer. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied Second Review: 1). OK 2). OK 3). Now that storm piping GPM loads have been added the following needs updated: A- 4" & 6" horizontal storm drains on plan page 2P201A are undersized -IPC 1106.2 (also be specific on slope) B- 736 GPM 6" horizontal storm piping is undersized on plan page 2P201B -IPC 1106.2 (also be specific on slope) C- 521 GPM 6" horizontal storm piping on plan page 2P201c is undersized. -IPC 1106.2 (also be specific on slope) D- The 2 different 27944 square foot GPM loads 998 & 872 don't correlate, The 736 GPM 6" horizontal storm piping is undersized. -IPC 1106.2 (also be specific on slope) E- Be specific on the 6" horizontal storm piping's slope on plan 2P201E to show compliance with the 487 GPM load. -IPC 1106.2 4). OK 5). OK 6). Same - Add NFPA 99 to plan page 2GI101 governing code schedules. -IPC 1202..... -IPC 2018 References 2018 NFPA99 not 2012 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 04/20/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 05/24/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Wrong plan st was uploaded for review. Closing so that they can resubmit the plans. |