Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM00130
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Buildings that exceed 30' shall be provided with fire department aerial access that shall conform with IFC 2018, Appendix D. Provide a diagram showing the distance from the road to the building. If the parking areas in front of the units serve each building for aerial access a note shall be placed on the cover stating that the parking lot against the building shall never have awnings or PV systems installed. Provide diagram of roof access ladder for each building. Plans shall show fire alarm is deferred to TFD Show location of FDC on the buildings per IFC 2018, Chapter 9, Section 912.2.1 FACP to be powered from an owner electrical panel Any fire protection plans in these drawings are for reference only not permit. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 01/25/2022 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | 1. An approved development plan is not to be used for construction of on-site utilities (e.g. water service to the building, building sewer, etc.). Provide the civil plans showing the installation of the water service to the building as part of the building plan set (i.e. not "for reference only"). Reference: Sections 107.2.1 and 107.2.6, IBC 2018. 2. The civil design for water service to the building is completely different from the plumbing design. Coordinate the two designs. |
| 01/27/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00114/BLDG #1, T22CM00127/BLDG #2, T22CM00128/BLDG #3, T22CM00129/BLDG #4, T22CM00130/BLDG #5, T22CM00131/BLDG #6, T22CM00132/BLDG #7 5301 S Nogales Hy – C-2, O-3 & R-2 Multi-Family (1st Review) This site is located in the C-2, O-3 & R-2 zones. 1. Zoning has reviewed the building plans for compliance with Development Package (DP) DP21-0312 and although the buildings appear to be in compliance with the DP Zoning cannot approve the building plans until the DP is approved. 2. Provide a break down of the number of each unit types and the square footage of each unit. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 01/27/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 02/04/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00114/BLDG#1, T22CM00127/BLDG#2, T22CM00128/BLDG#3, T22CM00129/BLDG#4, T22CM00130/BLDG#5, T22CM00131/BLDG#6 & T22CM00132/BLDG#7 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved 1. All exposed steel to be protected from corrosion using paint or galvanized. 2. All wood members which are exposed to weather are required to be protected. BUILDING REVIEW COMMENTS: Denied 1. The square footages for buildings #3 and #5 are not calculated correctly. Provide correctly calculated square footages for these buildings. 2. Provide occupant load calculations for the residential buildings in accordance with Section 1004. 3. Provide thorough egress plans for all buildings. 4. Provide a thorough code matrix that includes the calculations for the required amount of accessible units. 5. A132: Details 2 and 3 indicates a fire wall detail, however, it does not appear that fire walls are present in the project. Provide clarification. 6. A522: There no riser heights provided. Provide compliant riser heights for the stair details. MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E311 ELECTRICAL PLAN - BUILDING TYPES A & B - LEVEL 1: Missing Key Note #9, may have referenced Notes# 9. E321 ELECTRICAL PLAN - BUILDING TYPES C & C ADA LEVEL 1: Missing Key Note #9, may have referenced Notes# 9. E331 ELECTRICAL PLAN - BUILDINGS D LEVEL 1 & 2: Missing Key Note #9, may have referenced Notes# 9. E501 ELECTRICAL DIAGRAMS: Missing Keynotes #7 and #8 (probably lighting contactor and photocell info. PLUMBING REVIEW COMMENTS: Denied 1). Civil plan pages 7 & 8 show multiple meters & undersized water services to each Bldg. Plan pages P100 , 102, 202,302,402 show 2 water meters only for all Bldgs. & correct sized water services & mains. Plan Pages need to correlate. IPC A106.3.1 IPC 604 2). Water piping Floor plans & water piping risers need to illustrate the 1/2" water piping to the P6 wall boxes. Update all affected plumbing pages. -IPC A106.3.1 3). First floor water main & branch sizes not clear on plan pages P102, 202, 302, 402. -IPC A106.3.1 -IPC 604 4). Water piping detail #1 P602 detail #2 P402 don't correlate with each other or correlate with plan Pg P801 fixture schedule. ( Fixture numbers don't match ) -IPC A106.3.1 5). Fire main on P100 needs proper backflow protection. Tucson Amendment -IPC 608.17.4 6). Waste stack risers can't decrease in size at vent, needs to stay same size thru roof. -IPC 913.3 Update plan pages P501, 502, 503 7). Waste stacks undersized -IPC 913.4 Update plan pages P501, 502, 503 8). Unit 1A detail#1 on plan pages P201, 301, 401 directs you to the incorrect correlating riser. -IPC A106.3.1 9). On plan pages P101, 201, 301, 401 Notate each Bldg. drain stub out with it's total DFU load to show the Bldg. drain & sewer continuations are sized properly. -IPC 710.1 10). Add roof drain & overflow conductor sizing calculations that derive from FPC 1106.1, 1106.2, 1108.3, Tucson Amendment appendix B to plan pages A301 & A302 11). Add Storm drain piping horizontal slope to plan pages P101, 201, 301, 401 -IPC 1106.2 12). Add primary & secondary exterior wall nozzle discharge assembly detail to plan Pg. A311.. -IPC A106.3.1 , 1108.2 13). Combination primary/secondary roof drain assembly type shall have independent inlets & outlets. The roof drain specs for the type selected on P801 doesn't appear to comply with -IPC 1108.1 14). Update roof drain/overflow assembly detail on plan pg A311 to reflect the roof drain type on plan pg. P 801 & the types shown A302 & A302. so plan pages correlate -IPC A106.3.1 15). Add the type of water, sewer, storm piping materials to be used to plan page P801. -IPC A106.3.1, 605, 702.1, 1102.2 16). Add fixture spacing measurements to the plumbing plan pages. -IPC 404.2, 405.3.1 |
| 02/04/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | The DP needs to be approved before the building plans can be approved. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/04/2022 | VVERA1 | OUT TO CUSTOMER | Completed |