Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0044
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/23/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 03/02/2021 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | Standard rewquirements will apply during the development plan process. Existing and future right of way will be required to be shown on plan. 150 feet future right of way will be required to be shown (right of way future widening at MS&R intersections. Ensure setbacks are based on this requirement. |
| 03/02/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | If the occupancy load is over 100, fire sprinklers will be required. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 03/10/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0044 Address: 4702 E Grant Rd. Parcel(s): 121100020 Zoning: C-1 Existing Use: Automotive-Minor Service and Repair Proposed Use: Food Service TRANSMITTAL DATE: March 04, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Food Service is a permitted use in the C-1 zone; with use specific standards 4.9.13.0, 4.9.4.M.1 & 5. 3. Parking appears to be correct at 1 space per 100 sq. ft. GFA. Ensure any outdoor seating area is accounted for when calculating parking. 4. A cross access agreement may be necessary if parking spaces require backing into another parcel. 5. Ensure accessible parking spaces are the correct width at 16' width per space (parking space and cross hatch). 6. Short term Bike Parking is required at 1 space per 2,000 sq. ft. Gross Floor Area (GFA). Long term bike parking is required at 1 space per 12,000 sq. ft. GFA. The minimum requirement for each is 2 spaces. 7. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along both streets required. 8. The expansion of the development is greater than 25%. Full code compliance is required. 9. Submit setbacks, building height, and other dimensional standards with the development package. The lot is subject to MS&R setbacks. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
| 03/11/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Maximize water harvesting in landscape areas. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 03/16/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Needs Review |