Permit Number: T21CM09794
Parcel: 107031470

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM09794
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM09794



GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.



STRUCTURAL REVIEW COMMENTS:
Approved



BUILDING REVIEW COMMENTS:
Approved



MECHANICAL REVIEW COMMENTS:
Conditionally Approved
1. All corrections complied
2. Approved/Subject to field approval



ELECTRICAL REVIEW COMMENTS
Approved



PLUMBING REVIEW COMMENTS:
Denied
Second Review:
1). SAME-Add gutter and downspout sizing calculations to Plan Pg. A4.0, that derive from -IPC 1106.1, 1106.3, 1106.6
2 thru 5 OK
6). OK
7). OK
8). Now that the gas ventless fireplace combustion air (room size) calculations have been added to plan page M1.0, the room size information is incorrect, the ceiling heights are 10ft in all fireplace rooms not 16ft, & offices A105 & A104 are roughly each 1000 sq ft= and can only support 20,000 BTU each, that being said the 36" fire place chosen on plan page A10 is not dual sided so only one office would not be large enough to support 28,000 BTUs. ( *Note-The medicare/homecare rooms for the 60" dual sided ventless fireplace are still large enough even with 10ft ceilings)
9). OK


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
03/21/2022 JPEELDA1 FIRE REVIEW Approved
03/22/2022 IMONSHI1 ZONING REVIEW Approved
03/22/2022 IMONSHI1 ENGINEERING REVIEW Passed