Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM09661
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Sheet G1.01 Code Analysis references City as Peoria please correct to Tucson Deferred submittals for fire alarm, fire sprinkler shall be listed on Sheet G1.01 Provide exiting and distance plan Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 01/11/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 01/11/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09661 1740 E Fort Lowell Rd – C-1 TI Medical Office (1st Review) TRANSMITTAL: January 11, 2022 This site is located in C-1 zone, (4.7.21). Food service is an allowed use in the zone (Table 4.8-4) subject to Use Specific Standards 4.9.4.O.2 and 4.9.13.O. 1. Clearly demonstrate that there is a minimum 4’-0” clear from the top of the proposed ADA ramp to the building. 2. Demonstrate how the requirements of ICC A117.1-2009 Section 406 & 502 are met for the proposed ramp and parking space. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 01/11/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09661 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Verify that RTU 2, 3, 5 and 6 which are being reused are located at same locations as were previously placed. 2. New RTU-1 weighing 14,000 pounds (Drg S1.01) is placed on existing Roof Framing. Provide Structural Calculations justifying the adequacy of the roof framing to support new unit. 3. New RTU-4 weighing 13,000 pounds (Drg S1.01) is placed on existing Roof Framing. Provide Structural Calculations justifying the adequacy of the roof framing to support new unit. 4. Provide Seismic Calculations justifying the lateral loads resisting system of the existing building is adequate to support additional loading from the new RTU’s. 5. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Approval Pending 1. Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Denied E0.02 ELECTRICAL POWER DISTRIBUTION DIAGRAMS AND SCHEDULES: Need to perform and show short circuit calculations on Power Distribution Diagram for new Panel A to prove/show that 22 KAIC rating is adequate. This is a local Tucson City requirement for new panels. E3.01 ELECTRICAL POWER: Note 7 may not apply to room/receptacle locations. E4.01 ELECTRICAL SYSTEMS: Suggest to add note to refer to E0.2 Mechanical Schedule for connection/conductor information. PLUMBING REVIEW COMMENTS: Denied 1). WB-1 & WB-3 on plan pg, P0.01 need backflow devices that comply with IPC 608.17.1 2). Add 1" hot water pipe insulation to plan page P0.01 -IPC 607.2.1 607.5 3). add seismic supports to WH detail on plan page P7.01 -IPC 502.4 4). Water main BLDG. entrance location on plan pages P2.01 & C3.00 don't correlate. -IPC A106.3.1 |
| 01/12/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 02/02/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: 1. Is this for a new or existing activity application? - Please select New Application. 2. Submission Type - Select Floodplain Use Permit. 3. Project Name - Enter a name for your project. 4. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.) 5. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. 6. Description of Work - Enter in Floodplain Use Permit for…and then put a description of the work being done or reference the building permit number associated with this floodplain use permit. 7. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account. 8. Complete the Contractor, Owner and Architect/Engineer sections as applicable. 9. Supporting Documentation Upload - Provide a complete cost estimate for the project unless it is for a new build/separate structure. You may also provide additional documents you think will be helpful. 10. Sign the application and submit. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/02/2022 | VVERA1 | OUT TO CUSTOMER | Completed |