Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T21CM08953
Parcel: 137060950

Address:
5401 S 12TH AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM08953
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/03/2022 DBENOIT1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
11/26/2021 SBLOOD1 ENGINEERING REVIEW Passed
11/26/2021 JVINCEN1 FIRE REVIEW Approved
11/30/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
12/01/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
12/01/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Update the MEP Notes to reflect the editions of the Codes currently adopted by the City of Tucson. Reference: Section 107.2.1, IBC 2018.
2. Provide a design for the waste and vent piping including waste and vent isometrics. Specify the piping materials to be employed in this activity. Reference: Section 107.2.1, IBC 2018.
3. Provide a site plan showing the route of the building sewer and its connection to the public sewer. Reference: Section 107.2.1, IBC 2018.
4. Show how the water pipes are to be protected from freezing. Reference: Section 305.4, IPC 2018.
5. Provide the rim elevation of the next upstream sanitary manhole and the first-floor elevation. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.
6. Provide a cleanout immediately prior to entering the right of way. Reference: Pima County Standard Detail RWRD 401.
12/01/2021 ROBERT SHERRY WATER REVIEW Reqs Change Reduced pressure backflow prevention assemblies are required to be installed in locations accessible to Tucson Water. Show the location of the proposed water meter, backflow preventer, and the water service pipe on a site plan. Provide the size of the water meter serving the kiosk. Reference: Sections 107.2.1 and 107.2.6, IBC 2018 and Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf.
12/13/2021 STEVE SHIELDS ZONING REVIEW Needs Review ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM08953
5401 S 12th Ave – C-2
New Water Kiosk (1st Review)

TRANSMITTAL: December 13, 2021
This site is located in the C-2 zone (UDC 4.7.21).

1. Zoning has reviewed the building plans for compliance with DP21-0314 and although it appears that the plans match until the DP is approved zoning cannot approve the building plans.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
12/14/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/03/2022 DBENOIT1 APPROVAL SHELF Completed
01/03/2022 DBENOIT1 OUT TO CUSTOMER Completed
01/03/2022 DBENOIT1 REJECT SHELF Completed