Permit Number: T21CM08514
Parcel: 137055330

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM08514
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2021 SSHIELD1 ENGINEERING REVIEW Passed
11/03/2021 STEVE SHIELDS ZONING REVIEW Approved
11/03/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
11/23/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM08514

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

STRUCTURAL REVIEW COMMENTS:
Approval Pending
1. Inspector to verify any loading attached to the steel roof joists to be attached at the panel point. Otherwise, reinforcing to the steel joists will be needed to transfer the loading to the panel points.
2. Inspector to verify that the weights of new RTU's is less or equal to the RTU's being removed. Otherwise additional Structural Calculations will be needed for the adequacy of Roof Joists and Joist Girders.

BUILDING REVIEW COMMENTS:
Approved

MECHANICAL REVIEW COMMENTS:
Approval Pending
Approved /Subject to field approval

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
Denied
1). Add water & sanitary/vent piping materials to be used to plan page P1.0 or P3.0. IPC A106.3.1
2). Trap primer detail; #6 on P3.0 needs to show the shut off valve on the branch & delete the note " Without shut off valve in branch" IPC 606.2 #3
3). Beverage equipment( P21- P22 )- Pipe Backflow port discharge port piping to an indirect waste receptor as stated in Plumbing fixture schedule 'DCV' needs to be illustrated on P3.0 detail & P2.0. IPC 608.15.2.1
4). Add Urinal sidewall to center fixture spacing measurements to plan pg. CS4.0 or to P2.0 IPC 405.3.1
11/23/2021 ROBERT SHERRY WATER REVIEW Completed
12/06/2021 JPEELDA1 FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/06/2021 VVERA1 OUT TO CUSTOMER Completed