Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM08494
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/10/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM08494 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide Section 106 as marked on Foundation Plan Drawing S1.0. 2. Provide Section 205 as marked on Framing Plan Drawing S2.0. BUILDING REVIEW COMMENTS: Denied 1. Provide the list of applicable and enforced building codes that this project must comply to. 2. The occupancy class provided is different in various places throughout the plans. Provide the accurate occupancy class and correlate any applicable requirements. 3. No occupant load calculation provide. Provide an accurate occupant load calculation. 4. No reflected ceiling plan provided. Provide a reflected ceiling plan. 5. Provide a full truss package for review. 6. No wall schedule provided. Provide a detailed wall schedule along with typical wall section details. 7. No door schedule provided. Provide a detailed door schedule along with door tags and door details. 8. Provide a detailed list of the applicable special inspection that will be required along with all appropriate paperwork MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied 1. Please provide a prescriptive path or provide COMcheck calculations for the lighting. All mandatory requirements must be identified on the plans for compliance. PLUMBING REVIEW COMMENTS: Approved |
| 11/16/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Please provide a Code Analysis on this sheet, indicating applicable codes, occupancy classification, construction type, actual square footage of the addition, actual square footage of the existing, allowable square footage for all buildings combined, occupancy load of the addition, occupancy load for all buildings combined, plumbing fixtures required for all buildings combined, exit requirements, egress requirements, and accessibility requirements. Provide distance from existing fire hydrant to the furthest part of the building and a diagram showing as the hose lays not crow flys. Building will be 6,300 sq feet and will require fire flow of 2,250 GPM. Provide letter from Tucson Water showing that the fire flwo can be met and or install fire sprinklers. If installing fire sprinklers that shall be noted on the new submittal package drawings. Questions: Jennifer Peel-Davis 520-837-7033 Jennifer.Peel-Davis@tucsonaz.gov |
| 11/18/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 11/19/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 11/19/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 12/01/2021 | IMONSHI1 | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/01/2021 | VVERA1 | OUT TO CUSTOMER | Completed |