Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM07165
Parcel: Unknown

Address:
533 N 4TH AV

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM07165
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/29/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Clarify the status of the replacement hood. On sheet M1 it is consistently called out as "existing", not new, as noted on sheet A2. Is the exhaust fan new or existing? Reference: Section 107.2.1, IBC 2018.
09/29/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
09/30/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet A4; Hood Framing Plan: Please indicate and call out new framing on this plan.
2. Sheet A4; Section 1: Note 7 indicates a steel stud wall, and a note indicates to "see partition types". Please call out the stud size, gauge, and spacing on this section.
3. Sheet A4; Detail of Structure for Exhaust Hood: Please provide an enlarged detail for the connection of the unistrut supports to the existing joists.
4. General: Please provide structural calculations for the adequacy of the existing structure to support the new hood.
5. General: Please provide written responses to all review comments.
09/30/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
10/25/2021 JPEELDA1 FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/25/2021 VVERA1 OUT TO CUSTOMER Completed