Permit Number: T21CM05370
Parcel: 11702133A

Address:
1000 N STONE AV

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T21CM05370
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2021 JVINCEN1 FIRE REVIEW Approved
07/28/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide tempered water for the public restroom lavatories using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2018.
2. Provide a detail showing that the water heaters located above the ceilings will have adequate access and maintenance space. Reference: Sections 502.3 and 502.5, IPC 2018 and Article 210.70 (c), NEC 2017.
3. Provide an approved vacuum relief valve for the scheduled bottom-fed water heater that is located above the fixture outlets (the ASME temperature and pressure relief valve does not include a vacuum relief capability). Reference: Section 504.2, IPC 2018.
4. Provide a full-open valve for the water service at the building entrance. Reference: Section 606.1(2), IPC 2018.
5. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018.
07/28/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
07/28/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM05370
1000 N Stone Ave
New Restroom Bldg

TRANSMITTAL: July 28, 2021
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

Historic review required for new building.
07/28/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/28/2021 ROBERT SHERRY WATER REVIEW Completed
07/28/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
07/28/2021 PCAMARE1 ENGINEERING REVIEW Reqs Change FROM: Paul Camarena
PDSD Engineering Review Section

PROJECT: T21CM05370
1000 N Stone AV

TRANSMITTAL DATE: July 28, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Engineering Review Section comments were addressed.

01. COMMENT: Engineering has reviewed the plan and cannot approve at this time. Please address the following comments.


02. COMMENT: Engineering cannot approve until Development Package is approved.





If you have any questions about this transmittal, Contact Paul Camarena at Paul.Camarena@tucsonaz.gov
07/28/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
08/04/2021 NGARCIA3 OUT TO CUSTOMER Completed