Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T21CM05370
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 07/28/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide tempered water for the public restroom lavatories using approved devices conforming to ASSE 1070. Reference: Sections 416.5 and 607.1.2, IPC 2018. 2. Provide a detail showing that the water heaters located above the ceilings will have adequate access and maintenance space. Reference: Sections 502.3 and 502.5, IPC 2018 and Article 210.70 (c), NEC 2017. 3. Provide an approved vacuum relief valve for the scheduled bottom-fed water heater that is located above the fixture outlets (the ASME temperature and pressure relief valve does not include a vacuum relief capability). Reference: Section 504.2, IPC 2018. 4. Provide a full-open valve for the water service at the building entrance. Reference: Section 606.1(2), IPC 2018. 5. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. |
| 07/28/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 07/28/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM05370 1000 N Stone Ave New Restroom Bldg TRANSMITTAL: July 28, 2021 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. Historic review required for new building. |
| 07/28/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 07/28/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/28/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 07/28/2021 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Engineering Review Section PROJECT: T21CM05370 1000 N Stone AV TRANSMITTAL DATE: July 28, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Engineering Review Section comments were addressed. 01. COMMENT: Engineering has reviewed the plan and cannot approve at this time. Please address the following comments. 02. COMMENT: Engineering cannot approve until Development Package is approved. If you have any questions about this transmittal, Contact Paul Camarena at Paul.Camarena@tucsonaz.gov |
| 07/28/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2021 | NGARCIA3 | OUT TO CUSTOMER | Completed |