Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM05270
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2021 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T21CM05270 – New Shell Building Building Plan Review (1st Review) / Relate to [DP21-0111] 3350 E Medina Rd / I-1 Zoning TRANSMITTAL DATE: 7/2/2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Zoning cannot approve the building plans until the Development Package has been approved. 2. COMMENT: This site was platted as a condominium plat a block plat. It will be required to consolidate this site into a single parcel prior to approval. 3. COMMENT: Zoning will re review the building plans for consistency to the approved development package on the next submittal, more comments may be forthcoming. If you have any questions about this transmittal, Contact Iman Monshizadeh by email Iman.Monshizadeh@tucsonaz.gov or contact Elisa Hamblin, at Elisa.Hamblin@tucsonaz.gov |
| 07/20/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/28/2021 | EHAMBLI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 08/06/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 08/09/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | IFC 2018, 3206.7.5 Number of doors required. The required fire department access doors shall be distributed such that the lineal distance between adjacent fire department access doors does not exceed 125ft measured center to center. Questions: Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 08/23/2021 | PIMA COUNTY | 2ND PARTY REVIEW | REVIEW | Reqs Change | T21CM05270 RFC 2nd Party Comments 7/1/2021 ARCHITECTURAL COMMENTS: 1. Add the 2-1/2" steel studs used at the shaft walls to the stud table (allowable ht.) 2. Signage by separate permit, typical. 3. Provide a separate submittal (PDF documents) of Special Inspection Certificates as required by sheet S0.0, including: Soils, Concrete, Structuralf Welding and high strength bolting, Cold-formed structural steel framing, wood (roof diaphragm), Approved fabricators, Post installed anchors in concrete and masonry. Built-up roofing installation. PLUMBING COMMENTS: 1. There is a sewer pipe exiting the building shown on the site plan, but there is no plumbing shown below the slab. Is there no sewer below the slab? MECHANICAL COMMENTS: No comments. ELECTRICAL COMMENTS: 1. Provide an Outdoor Lighting Code calculation per Tucson/Pima County OLC ordinance. Weblink: https://www.tucsonaz.gov/files/pdsd/codes-ordinances/2012_outdoor_lighting_code_.pdf |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/09/2021 | VVERA1 | OUT TO CUSTOMER | Completed |