Permit Number: T21CM05210
Parcel: 13711425D

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM05210
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2021 JVINCEN1 FIRE REVIEW Approved
07/06/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/07/2021 ROBERT SHERRY WATER REVIEW Completed
07/07/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Provide general room exhaust for any cooking appliance that does not require the installation of a Type II hood (e.g. Turbochef oven, combo steam oven, hot dog roller grill, Pizza warmer). The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.1, exception 2 and 507.3, IMC 2018.
07/07/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Appliances (e.g. steam oven) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Section 608.14.1, IPC 2018 require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 608.1 and 608.3, IPC 2018
2. Provide a cleanout for the new 3-inch fixture branch. Reference: Section 708.1.1, IPC 2018.
07/15/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
07/23/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
07/23/2021 SSHIELD1 ENGINEERING REVIEW Passed
07/23/2021 STEVE SHIELDS ZONING REVIEW Passed