Permit Details

Status:
Issued
Type:
Commercial Building
Address NEW:
1720 W IRVINGTON RD
Apply Date:
06/23/2021
Applicant:
Description:
TI:CIRCLE K

Permit Reviews

Permit Number - T21CM05210
Permit Status: Issued
Permit Description: TI:CIRCLE K
Start Date Submittal Complete Date Status  
02/23/2022 RESUBMITTAL 02/24/2022 COMPLETED Review Details
06/23/2021 COMMERCIAL - TI 07/23/2021 COMPLETED Review Details

Conditions

Permit Number - T21CM05210
Permit Status: Issued
Permit Description: TI:CIRCLE K
Date Description Comments
12/08/2022 COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED.

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM05210
Permite Description: TI:CIRCLE K
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - LCBU - Building Final N/A Not Ready
10/26/2022 COT - LCME - Mechanical Intermediate N/A Not Ready
10/26/2022 COT - ENGR - Site - Assurance Release N/A Not Ready
10/27/2022 COT - LCBU - Framing N/A Not Ready
10/26/2022 COT - LCME - Mechanical Final N/A Not Ready
10/27/2022 COT - LCEL - Electrical Final N/A Not Ready
10/26/2022 COT - LCPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: T21CM05210
Permit Description: TI:CIRCLE K
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/26/2022 COT - LCPL - Rough Soil Passed {Activity date: 08/26/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, okay to cover} ; {Activity date: 08/17/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VVERA1 - Partial for floor sinks at soda and coffee bar areas, okay to cover progress progress areas} ; {Activity date: 08/16/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Leak at first floor drain on other side of bathroom wall.

}
09/14/2022 COT - LCEL - Electrical Intermediate Passed {Activity date: 09/14/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. New 200 amp panel.} ; {Activity date: 09/13/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval clamp MC cable in walls at outlets, conduit above ceiling not clamped, SOJ cable pulled out of j box, label j boxes above ceiling

} ; {Activity date: 09/09/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Not ready drywall installed prior to electrical inspection, customer was advised the electrical contractor can supply a letter to the city of Tucson stating that he takes full and all responsibility for the install in the wall and on the job and meets 2017 NEC requirements}
09/14/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 09/14/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. New back flow system installed in building.}
09/26/2022 COT - LCEL - Electrical Above Ceiling Passed {Activity date: 09/26/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/14/2022; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Above ceiling to be completed when mechanical portion is complete.
}
10/26/2022 COT - FCON - Sprinkler - Final Passed
10/26/2022 COT - FCON - Fire - Final Passed
10/26/2022 COT - FCON - Alarm - Final Passed