Permit: T21CM05210
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
1720 W IRVINGTON RD
Address NEW:
1720 W IRVINGTON RD
Apply Date:
06/23/2021
Applicant:
Description:
TI:CIRCLE K
Permit Reviews
Permit Number - T21CM05210
Permit Status: Issued
Permit Description: TI:CIRCLE K
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/23/2022 | RESUBMITTAL | 02/24/2022 | COMPLETED |
| 06/23/2021 | COMMERCIAL - TI | 07/23/2021 | COMPLETED |
Conditions
Permit Number - T21CM05210
Permit Status: Issued
Permit Description: TI:CIRCLE K
| Date | Description | Comments |
|---|---|---|
| 12/08/2022 | COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T21CM05210
Permite Description: TI:CIRCLE K
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | COT - LCBU - Building Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Intermediate | N/A | Not Ready | |
| 10/26/2022 | COT - ENGR - Site - Assurance Release | N/A | Not Ready | |
| 10/27/2022 | COT - LCBU - Framing | N/A | Not Ready | |
| 10/26/2022 | COT - LCME - Mechanical Final | N/A | Not Ready | |
| 10/27/2022 | COT - LCEL - Electrical Final | N/A | Not Ready | |
| 10/26/2022 | COT - LCPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM05210
Permit Description: TI:CIRCLE K
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2022 | COT - LCPL - Rough Soil | Passed | {Activity date: 08/26/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved, okay to cover} ; {Activity date: 08/17/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VVERA1 - Partial for floor sinks at soda and coffee bar areas, okay to cover progress progress areas} ; {Activity date: 08/16/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - not ready. Leak at first floor drain on other side of bathroom wall. } |
|
| 09/14/2022 | COT - LCEL - Electrical Intermediate | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. New 200 amp panel.} ; {Activity date: 09/13/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval clamp MC cable in walls at outlets, conduit above ceiling not clamped, SOJ cable pulled out of j box, label j boxes above ceiling } ; {Activity date: 09/09/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Not ready drywall installed prior to electrical inspection, customer was advised the electrical contractor can supply a letter to the city of Tucson stating that he takes full and all responsibility for the install in the wall and on the job and meets 2017 NEC requirements} |
|
| 09/14/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/14/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. New back flow system installed in building.} | |
| 09/26/2022 | COT - LCEL - Electrical Above Ceiling | Passed | {Activity date: 09/26/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/14/2022; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by VVERA1 - Partial. Above ceiling to be completed when mechanical portion is complete. } |
|
| 10/26/2022 | COT - FCON - Sprinkler - Final | Passed | ||
| 10/26/2022 | COT - FCON - Fire - Final | Passed | ||
| 10/26/2022 | COT - FCON - Alarm - Final | Passed |