Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM05104
Parcel: 125073370

Address:
2246 E 6TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM05104
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change After Zoning approval provide a complete plan set for Building review including all pages listed on the index.
12/28/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05104
2246 E 6th St. – R-1
Two (2) Story Addition (2nd Review)


TRANSMITTAL DATE: December 28, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. Based on a wall height of 26’-‘6 the required street perimeter yard setback to 6th St is 26’-6” with the proposed setback of 16’-7”. A Board of Adjustment for Variance is required. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf, contact Mark Castro with any questions, Mark.Castro@tucsonaz.gov.

The following may also be processed through the Board of Adjustment:

2. Based on a wall height of 29’-0” the required street perimeter yard setback to Wilson Ave is 29’-0” as measured to the outside edge of the nearest adjacent travel lane, proposed setback is 20’-0”. UDC Article 6.4.5.C.2 & Table 6.4.5.C-1 ADT over 140 but less than 1,000.

3. Based on a wall height of 23’-0” the required perimeter yard setback from the proposed 2nd story covered porch to the west property line is 15’-5” proposed setback is 5’-0”.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

4. Based on a wall height of 26’-6” the required perimeter yard setback from the proposed 2nd story addition to the west property line is 17’-8” proposed setback is 11’-5”.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov