Permit Number: T21CM05104
Parcel: 125073370

Address:
2246 E 6TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM05104
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05104
2246 E 6th St.
Two (2) Story Addition (1st Review)


TRANSMITTAL DATE: July 13, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. As 6th Street is a collector listed on the COT MS&R map the street perimeter yard setback is based on UDC Article 6.4.5.C.2 & Table 6.4.5.C-1 ADT of 1,000 or Greater and measured to the back of future curb. Back of future curb shall be located 9’-6” from the future property line. Future property line will be 45’ south of centerline of 6th St. Show the future curb, future property line and provide a street perimeter yard setback dimension from back of future curb to the proposed addition. Based on the dimensions shown on the plan once the future curb & property line are shown correctly the back of future curb will be 4.1’ north of the existing property line with the proposed perimeter yard setback being 16.6’. Based on a wall height of 26’-‘6 the required street perimeter yard setback to 6th St is 26’-6” with the proposed setback of 16’-7”. Per UDC Article 3.11.1.D.1.d a DDO cannot modify an overlay requirement such as a Major Streets and Routes setback therefore a Board of Adjustment for Variance is required. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf, contact Mark Castro with any questions, Mark.Castro@tucsonaz.gov.

The following may also be processed through the Board of Adjustment:

2. Based on a wall height of 29’-0” the required street perimeter yard setback to Wilson Ave is 29’-0” as measured to the outside edge of the nearest adjacent travel lane, proposed setback is 21’-0”. UDC Article 6.4.5.C.2 & Table 6.4.5.C-1 ADT over 140 but less than 1,000.

3. Based on a wall height of 23’-0” the required perimeter yard setback from the proposed 2nd story covered porch to the west property line is 15’-5” proposed setback is 5’-0”.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

4. Based on a wall height of 29’-0” the required perimeter yard setback from the proposed 2nd story additon to the west property line is 19’-5” proposed setback is 11’-3”.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
07/15/2021 SBLOOD1 ENGINEERING REVIEW Passed
07/15/2021 AWARNER1 NPPO REVIEW Passed
07/15/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set for review including all pages listed on the index.
07/30/2021 JVINCEN1 FIRE REVIEW Approved