Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM04901
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 07/06/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/07/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM04901 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied Structural steel, components and fasteners for the roof screen are to be protected against corrosion in accordance with AISC 360 Section B.13 as indicated in IBC 2018 Section 2203.1. 2. Designer is to coordinate venting and drainage hole requirements for HSS tube members that are galvanized using the hot-dip galvanizing process. Provide for plugs as needed. AWS D-19.0 calls for welds on galvanized steel to be free of zinc. Field welds on galvanized parts requires the removal of the zinc coating in the area of weld. Provide zinc paint (approved by the galvanizer) and apply as required to the weld and steel area to provide protection. 3. Screen wall column locations shown along line 6.6 and the screen wall is shown along line 6.7 on Drawing S1.2. Coordinate screen wall location with Architectural Drawings. 4. Section D4 on Drawing S3.1 shows combined footing size as 13’x6’. Drawing S1.1 shows combined footing size as 13’x5’. Investigate and make corrections as needed. 5. Refer Drawing S1.2, Roof Framing Plan. Section A2/A4.2 is called out. Drawing A4.2 is not submitted in this submittal. Submit Drawing A4.2. 6. Refer Drawing S1.2, Roof Framing Plan. Section A3/A4.2 is called out. Drawing A4.2 is not submitted in this submittal. Submit Drawing A4.2. 7. Refer Drawing S1.2, Roof Framing Plan. Section A1/A4.3 is called out. Drawing A4.3 is not submitted in this submittal. Submit Drawing A4.3. 8. Refer Drawing S1.2, Roof Framing Plan. Section A1/A4.4 is called out. Drawing A4.4 is not submitted in this submittal. Submit Drawing A4.4. BUILDING REVIEW COMMENTS: Denied The occupant load factor for business use is 150 sq ft. per person. This will not affect the occupant load but please correct. 2. Sheet A1.5 provides documentation for alternative for an alternative acoustical ceiling suspension, however, on sheet A1.3 a standard seismic bracing detail is provided for a lay in ceiling. Correlate these details and provided an accurate bracing detail for the proposed acoustical ceiling. MECHANICAL REVIEW COMMENTS: Denied 1.provide quantity of CO2 on the premises (imc2018,106.3.1) 2. provide manufacturers kitchen hood specs (imc2018,106.3.1) 3. provide isometric gas pipe plan with gas pressure and pressure drop info (imc2018,106.3.1) 4. provide ventilation table (imc2018,106.3.1) ELECTRICAL REVIEW COMMENTS Conditionally Approved E5.1 ELECTRICAL DIAGRAMS: Should increase size of grounding conductor for ground rod or concrete encasement (Ufer) ground so that it is the primary grounding. Currently the grounding to building steel and water line have the largest grounding conductors E5.3 CONTROL SYSTEMS PLAN: Should call out all cables that might be installed in duct to be plenum rated. PLUMBING REVIEW COMMENTS: Denied 1. Amend sheet G.1 Applicable codes to include the local amendments for the 2018 Plumbing code. 2. Sheet P1.2 must be revised to reflect the requirements of IPC 1003.3 as amended by the local jurisdiction. The following fixtures are required to be connected to the grease interceptor: All Floor sinks, and Hand sinks 3. Update Sheet P4.1 to reflect the calculation table for the Grease Interceptor as per local amendment |
| 07/13/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM04901 5050 E Valencia Rd New Whataburger (1st Review) TRANSMITTAL: June 13, 2021 This site is located in the C-2 zone (UDC 4.7.22). Food Service is a permitted use in this zone (Table 4.8-4). See Use Specific Standards 4.9.4.M.1 and 4.9.13.P. 1. Zoning has reviewed the building plans for compliance with DP21-0172 and although it appears that the building matches what is shown on the DP, until DP21-0172 is approved Zoning cannot approve the building plan. 2. The development package sheets provided in the building plan either need to be the approved stamped sheets, marked for reference only or removed from the building plans. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 07/13/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
| 07/20/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Development Package must be approved first. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/20/2021 | VVERA1 | OUT TO CUSTOMER | Completed |