Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM04899
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Plans shall have the following information on them: Will the building have fire sprinklers Will the building have a fire alarm systm Occupant Load of the building Completed Code Review Section. If you have any questions, please call or email me: Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 07/06/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Approv-Cond | STRUCTURAL REVIEW COMMENTS: Conditionally Approved 1. Designer is to coordinate venting and drainage hole requirements for HSS tube members that are galvanized using the hot-dip galvanizing process. Provide for plugs as needed. AWS D-19.0 calls for welds on galvanized steel to be free of zinc. Field welds on galvanized parts requires the removal of the zinc coating in the area of weld. Provide zinc paint (approved by the galvanizer) and apply as required to the weld and steel area to provide protection. 2. Columns C2 supporting the Canopy are not called out on Plan, identify those columns on Plan. 3. The Top/Bottom of Foundations are not called out on Floor Plans, make revisions as necessary. 4. Typical Steel Column Base Plate details for W Sections are not shown anywhere on the Structural Drawings. Make revisions to the Drawings as necessary. |
| 07/08/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/13/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM04899 4702 E Grant Rd New Food Service (1st Review) TRANSMITTAL: June 13, 2021 This site is located in the C-1 zone (UDC 4.7.20). Food Service is a permitted use in this zone (Table 4.8-4). See Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Zoning has reviewed the building plans for compliance with DP21-0147 and although it appears that the building matches what is shown on the DP, until DP21-0147 is approved Zoning cannot approve the building plan. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 07/13/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 07/20/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Development package must be approved first. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/20/2021 | VVERA1 | OUT TO CUSTOMER | Completed |