Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM03856
Parcel: 106070670

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM03856
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2021 STEVE SHIELDS ZONING REVIEW Approved
10/05/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM03856
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019.

The Inclusive Home Design notation may be removed from this addition plan.

FLOOR PLANS:

1. Show the functional name of each proposed room and each adjacent room, R106.1.1. Include all rooms below the replaced roof.
2. Show all removed items including walls, doors, windows, fixtures and appliances in the construction area. R106.1.1.

STRUCTURAL PLANS:

1. Show the size of the carport beam which will support the proposed truss. The integrity of the existing structure requires verification for supporting the new loads, R301.1.3.
2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1.

SECTIONS - DETAILS:

1. Show the minimum 12” footing depth below the undisturbed ground surface with minimum 6” clearance above the ground, R317.1 item 5, a stem may be required at existing floor levels. Update detail #4.
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Notate detail #5.

PLUMBING PLANS:

1. Show any plumbing alterations, 2018 IRC.

MECHANICAL PLANS:

1. Show any mechanical alterations, 2018 IRC.

ELECTRICAL PLANS:

1. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2.
2. Protection of all new and extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16 & 17.

OUTDOOR LIGHTING CODE

1. Show any proposed fixtures as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review