Permit Number - T21CM03291
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 04/27/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 04/27/2021 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 04/28/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 05/04/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. General: Please provide structural calculations for the AVRA Vault Foundation/Wall Plan (Sheets 22 and 23), the Santa Cruz Vault Foundation/Wall Plan (Sheets 24 and 25), and the Control Building (Sheets 26 through 31). 2. General: Please provide a Special Inspections Certificate with Parts A and B complete. |
| 05/11/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. #1. Ref; Plan Sheet 42 of 58. There is a notation above the bold "SINGLE LINE DIAGRAM" stating "NEW WORK IS SHOWN DARK, EXISTING IS SHOWN LIGHT" . It appears that all is shown in dark. Is this the case? #2. Where is the new electrical service located? #3. Ref; Plan Sheet 37 of 58. Is the control building and associated electrical equipment new? Please clarify. Ref 2018 IBC 107.2.1, 2017 NEC |
| 05/17/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM03291 990 E Valencia Rd Water Utility TRANSMITTAL: May 17, 2021 This site is located in the I-1 zone (UDC 4.7.29). Utility Distribution System is a permitted use subject to Use Specific Standards 4.9.11.B.2, .3, & .5 and 4.9.13.Q. 1. As you are proposing a new building on this site A Development Package (DP) is required that meets the requirements of the checklist for Minor Changes to Commercial/Industrial Sites located at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf, shall be submitted and approved prior to approval of this permit. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 05/20/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | See zoning comment for need of DP. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 06/03/2021 | LBOWERS1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |